Name

Values

Description

ZT

0 Zero

tracking

disabled

(Zero Tracking)

0.2

Zero

tracking

at

± 0.2 graduations

0.6

Zero

tracking

at

± 0.6 graduations

1 Zero

tracking

at

±1 graduation

3

Zero tracking at

± 3 graduations

This scale will be re-zeroed within the chosen graduation

DA OFF

Digital averaging disabled

.

(Fast update – recommended for

applications

(Digital Average)

where speed is a prime consideration, such as filling

operations)

LOW

Digital averaging at low

(Norma setting for parts counting)

MED

Digital averaging at medium

(Normal weighing applications)

HI

Digital averaging at hi

(

Recommended for areas with heavy vibrations)

ZR

1.5

Zero

range

at

1.5

percent

of

full

scale

(Zero Range)

100

Zero range at 100 percent of full scale

U

LB.

Pounds

only

(Units)

KG

Kilograms

only

G

Grams

only

LB/KG

Pounds

to

Kilogram

conversion

LB/G

Pounds to Grams conversion

KG/G

Kilogram to Gram conversion

ALL

Pounds, Kilogram, Grams conversion counting operation

is disabled

MB

0

Motion band disable

(Not recommended for normal operations)

(Motion Band)

0.1

Motion band at 0.1 graduations

(Most sensitive setting counting)

0.2

Motion band at 0.2 graduations

(Counting and weighing with printer)

0.3

Motion band at 0.3 graduations

(Light vibrations and air movement

0.4

Motion

band

at

0.4

graduations

(Standard setting)

0.5

Motion

band

at

0.5

graduations

0.6

Motion

band

at

0.6

graduations

0.7

Motion

band

at

0.7

graduations

0.8

Motion

band

at

0.8

graduations

0.9

Motion

band

at

0.9

graduations

(Least sensitive)

1.0

Motion band at 1.0 graduations (

Least sensitive)

SM

OFF

Setpoint

Off

(Setpoint Mode)

CUT

Setpoints set for cutoff operations

COM

Setpoints set for comparator operations

SA

NO

Normally

open

(Setpoint Activation)

NC

Normally

closed

SD

QTY

Setpoints

operate

will

quantity

displayed

(Setpoint Data)

GRS

Setpoints

operate

with

gross

displayed

NET

Setpoints operate with net displayed

SS

F

Setpoints will activate even when the scale is in motion

(Setpoint Stable)

T

Setpoints will activate only when the scale is stable








PARAMETERS SETUP AND CALIBRATION