TeeJet TASC-6600 User Manual

Page 14

Advertising
background image

2-2

TASC-6000, 6300, 6600

98-05010

Rev. - 1

A. Use the following switch settings to select the desired drive method (You should have to do this only once

unless you change your equipment configuration.).

Power

OFF

Mode selector

SET-UP

Display selector DISTANCE

B. Turn the rate selector switches, for any channels (1 - 6) that you want set to non-peristaltic to "ON". Any

channels left "OFF" are set to the peristaltic mode.

C. Hold the INC/DEC switch down while turning on the TASC power. After completing the start up routine, the

display settles on a series of o's and -'s. The o's correspond to the channels that are set to non-peristaltic drive

and the -'s indicate peristaltic channels.

o o -

Indicates channel 1 and 2 are set to non-peristaltic drive and channel 3 is set for peristaltic.

D. If it is ever necessary to reset the channel configuration, simply repeat the above procedure selecting the desired

switch configuration.

E. Whenever the TASC power is turned ON, the console momentarily displays the drive status of the chemical

applicator channels (unless all channels are in peristaltic mode).

2.3 SETTING APPLICATION RATES

2.3.1 SETTING CARRIER APPLICATION RATE

TASC is designed to maintain a constant, preselected application rate for the carrier, including chemical, as it exits the
sprayer. In order for TASC to do this, the operator must enter the desired carrier application rate. NOTE: The minimum
Carrier Rate must exceed the total Chemical Rate by at least one Gal/Ac (L/Ha).

A. Set the console switches to the following positions:

Power

ON

Mode Selector SET-UP
Display Selector CARRIER, APPL. RATE

The display shows the current Carrier plus Chemical application rate (Gal/Ac or L/Ha).

B. Use the INC/DEC switch to set the value displayed to the new desired rate.

NOTE: Setting the Carrier Application Rate to 0.0 shuts off the flow control function.

2.3.2 SETTING CHEMICAL APPLICATION RATE

The TASC-6300 and 6600 consoles are designed to maintain a preset injection rate for each injection pump. To do this the
operator must enter the desired Application Rate (Oz/Ac or L/Ha) for each pump.

A. Set the console switches to the following positions:

Power

ON

Mode Selector

SET- UP

Display Selector

CHEMICALS, CHEM. RATE

Pump Switch #1

CENTER, ON POSITION