This is often caused by loss of power
to the valve.

Incorrect switch sequence is selected on
the console.

Communications problem with pump
Channel slave board or Data Link.

Memory error.

This is often the result of a poor
battery connection.

The vehicle electrical system voltage
has fallen below about 10.0 VDC.

Internal diagnostics.

Unable to print.

Value to be displayed exceeds the
maximum allowable size.

Occures when the vehicle is setting still
with the GSO, booms and any injection
pump turned on.

The Display Selector on a TASC 6000
console has been set to one of the
CHEMICAL (injection pump) positions
and this type of console has no injec-
tion capabilities.

Err 5
PUMP-F

Err

Err C

Err E

Err L

Err n, hook
(backward 7)

Err P

OFLO

- FLO

none
(TASC 6000 Only)

TASC ERROR MESSAGES, COMMON CONDITIONS AND SOLUTIONS

FIRST Check the battery connections, this is the MOST common fault.

ERROR CODE

CAUSE

REMEDY

Check fuse at battery and on valve (optional).
Replace if defective.

Check wiring and battery connections.

Consult Operator's Manual for the correct switch
sequence.

Return console to Mid-Tech for repairs.

Hold down the decrease switch until the alarm
stops. Check to see which constants have been set
to zero and re-enter the correct values.

Establish good ground and battery connections.
This is the most common fault when system is
acting erratically.

Check and service or replace the vehicle battery.

Check and service or replace the vehicle alternator/
voltage regulator.

May appear from time to time. A momentary
appearance, followed by no other problems, can be
safely ignored. If occurs frequently, or if comes on
and stays on, contact your Mid-Tech dealer.

This message should appear only if you have a
Mid-Tech printer attached to the TASC console.
Console has received a print request from the
printer but cannot respond until the current control
function is completed.

Hold down the decrease switch until the display re-
sets to zero.

Error will clear as soon as the vehicle starts moving
or GSO, booms or pumps are turned off.

Use a TASC 6300 or 6600 console if injection
capabilities are required.