TeeJet TASC-6600 User Manual

Page 28

Advertising
background image

2-16

TASC-6000, 6300, 6600

98-05010

Rev. - 1

The TASC Console display cycles through its normal Power Up testing routine and momentarily displays the software
level installed. After about two seconds the display changes to "Stnrd", and remains in this condition until the DEC.
Switch is released. The Console then displays the current Flow Meter Calibration Number.

The TASC System is now back to its standard configuration. The system remains in standard until the Reflow Option is
activated again.

2.12 OPERATING UNDER EXTERNAL RATE COMMANDS

When the TASC 6000 series console is operating under external rate commands, it must be connected to the computer
running the field mapping program, through a 405-0069-96V or 78-05077 Data Link. Minimum and maximum rates must be
programmed into the Rate Switch STANDARD RATE and ALT.-RATE positions respectively and the Rate Switch must
be placed in the Alt.-Rate position. The instructions, received with the Data Link, explain in more detail, how to set up the
control console and Data Link. NOTE: The "Percent Rate Change" function is disabled when operating in the "External
Control" mode.