2.12.2. REFLOW SET UP

Before operating the sprayer in the Reflow mode, there are some critical set-up steps which must be taken.

1. Using the methods recommended by the sprayer manufacturer, adjust the reflow bypass valves so that they will allow

reflow at the same flow rate that the individual boom section would apply, if it were activated. For example: if the boom
section would ordinarily spray 1 gallon per minute at normal working pressure, then the reflow valve should be
adjusted to reflow 1 gallon per minute, at the same pressure, when the flow to that boom section is diverted to the
reflow line.

2. Make sure all reflow boom widths are properly established in the TASC Console (see section 2.5).

3. Make sure that boom section "C" is set to the total width of the boom when all reflow boom sections are operating. For

example; if the sprayer is using 6 booms in the reflow operation, each boom being 10 feet in length, the total Boom
Width "C" is be 720 inches.

4. All TASC Console boom positions which are not being used in the reflow spraying operation, must be set to 0.0 width.

For example; if only booms 1 through 6 are being used for reflow, booms 7, 8 and 9 must be set to zero for the TASC
Console to work properly.

5. Make sure the proper Flow Meter Calibration number is entered in the TASC Console. See section 2.6. of the TASC

Manual (Flow Meter Calibration).

2.12.3. ESTABLISHING THE REFLOW OPTION

The following procedure will establish the Reflow in the TASC Console. Once the Reflow Option has been selected, the
Console will remain in the Reflow Option, even through normal Power Down and Power Up, until Reflow is cancelled.

Power

OFF

All pumps

OFF

All booms

OFF

Display Selector

CARRIER, TOTAL APPLIED

Mode Switch

SET-UP

Hold INC./DEC. Switch to INC. while turning Power ON

The TASC Console powers up and displays its initial test sequence and the software level installed. After approximately
two seconds, the display reads "rEFLO", and that message continues to be displayed until the INC. Switch is released.
The TASC System is now set to the Reflow Option.

When the INC. Switch is released, the display shows 0.0 for the flow meter calibration number. When all reflow boom
sections are turned "ON", the flow meter calibration number is displayed normally. As boom sections are turned "OFF",
the flow meter calibration number will increase proportionately to the boom width which is still active.

2.12.4. CANCELLING THE REFLOW OPTION

The Reflow Option is cancelled with the following procedure.

Power

OFF

All boom switches

OFF

All product pumps

OFF

Display Selector

CARRIER, TOTAL APPLIED

Mode Switch

SET-UP

While holding the INC./DEC. Switch to DEC, turn Power ON