System diagnosis (only when the n-8000mi is used), Line status diagnosis, Network status diagnosis – Toa N-8000 Series Ver.1.41 User Manual

Page 94: P. 2-42

Advertising
background image

2-42

Chapter 2: FUNCTIONS AND OPERATION

4.12. System Diagnosis (only when the N-8000MI is used)

The N-8000MI diagnoses the system condition, and provides its results at the contact output terminal as open
or closed contact. The system diagnosis is performed in a way that the N-8000MI connects the target
equipment via the network.
The contact output terminal is closed only when an abnormality has been detected.
Thereafter, its closed terminal opens when the N-8000MI judges the condition to be normal.
This function aims to diagnose the exchange's line status and the network status of the connected equipment.
Use the N-8000 Software program to perform settings for the network lines and equipment to diagnose. (Refer
to

p. 5-44

.)

Note
Diagnosis is performed at the set time intervals*. Therefore, the diagnosis results are not obtained in real time.
The system condition, even if a change occurs, cannot be detected in the intervals from a diagnosis to the
next diagnosis.

* Diagnosis results are renewed every 20 seconds or less.

4.12.1. Line status diagnosis

If the N-8000EX or N-8010EX exchange's line to be diagnosed shows the status below, the N-8000MI judges
the line to be abnormal.

• Station's CPU failure
• Line synchronization error
• Station number registered but not connected

4.12.2. Network status diagnosis

The N-8000MI attempts to communicate with the network-connected equipment to be diagnosed such as
exchange, Multi interface unit, or IP station. If no response is detected, the N-8000MI judges such equipment
to be failed.

[Example]

Diagnosis results can be displayed on a status indicator.

Status indicator

N-8000MI

N-8000EX

N-8010EX

N-8000MI

Contact outputs

Network