8. GAS INLET

 The gas inlet of the heater is located on the left side of the unit by design.
 The heater is NOT to be mounted to where the gas inlet is on the right side as it may cause

damage to the heater and doing so will void the product warranty.

















9. MOUNTING

 The heater may be mounted at a 0 degree angle or at a maximum of a 30 degree angle in

reference to the floor. The heater must always be horizontal to the floor.

o WARNING: If the heater is mounted at greater than a 30 degree angle will cause

improper flue exhaust of combustion gases which may result in damage to the front
grille.

NOTE: Use only the mounting brackets provided by the manufacturer. Heater must be leveled

only on a Horizontal Axis but can be angled to a maximum of 30 degrees in reference to the
floor. DO NOT mount the heater on a vertical axis. Such installation is considered unsafe and
improper and will automatically VOID the product’s warranty.

 Clearance around the heater must be maintained for prevent fire hazard and to allow proper

ventilation of the heater. Heater must be in a location that allows uniform air pressure around
the entire heater.













10

Angle Mounted Horizontal Mounted

Heater must be installed such that combustion

exit through top vents.

INCORRECT INSTALLATION. GAS IN FROM THE RIGHT SIDE

CORRECT INSTALLATION. GAS IN FROM THE LEFT SIDE

Incorrect Mounting

Radiant Heat

Vent

Vent

Combustion gases exit

through the front grille.