Selecting mounting location – Twin Eagles TEGH48 User Manual

Page 9

Advertising
background image

SELECTING MOUNTING LOCATION

G

AS

I

NFRARED

H

EATER

When selecting a location to install the

T

WIN

E

AGLES

Gas Infrared Heater, all the following

factors must be met before the installation process:

1. ANCHORING TO WALL OR CEILING

If the heater is not anchored to support at least 100 lbs. (45 ½ kg.) it could be a

Suspension Hazard. Failure of the supports can result in death. Local codes regarding head

clearance requirement must be observed. Heaters shall be mounted in a fixed position independent

of gas and electrical supply.

2. COMBUSTIBLE MATERIALS

Combustible means material that can quickly catch fire if it comes in contact with sparks or

fire. The Twin Eagles heater is a remote controlled unit that strictly requires that each heater must

be installed such that the “MINIMUM CLEARANCE TO COMBUSTIBLES” are always met

and maintained. CAUTION should be taken when heaters are used near glass, vinyl siding or

other temperature sensitive construction materials. In some cases it may be necessary to increase

the clearance around the heater to avoid damage to vinyl siding. Check with the manufacturer of

the material siding for details

3. WEATHER CONDITIONS

This heater has been designed, tested and approved for outdoor installation and has passed

basic wind and rain tests. However, do not expose the heater under extremely harsh weather

conditions and very windy areas.

4. FIRE SPRINKLERS

Fire Sprinklers must be located at an appropriate distance from each heater to avoid accidental

activation of the sprinkler. Ethylene glycol, propylene glycol, antifreeze solutions or any other

potentially flammable substance must never be used in fire sprinkler systems where heaters

are present as these substances may become flammable when heated. A fire sprinkler

7

NOTE: Use only the mounting brackets provided by the manufacturer. Heater must be

leveled only on a Horizontal Axis but can be angled to a maximum of 30 degrees in

reference to the floor. DO NOT mount the heater on a vertical axis. Such installation is

considered unsafe and improper and will automatically VOID the product’s warranty.

Advertising