Troubleshooting

Fault

Possible cause

Remedy

❑ Pump fails to start, sys-

tem becomes vented.

➨ Mains not plugged in, failure

of electrical supply?

✔ Plug in mains plug. check

mains fuse.

➨ Motor overloaded?

✔ Allow motor to cool, identify

cause of failure.

➨ Pressure control device de-

fective?

✔ Contact your local distributor.

➨ Internal fuse blown (BVC 21

NT VARIO)?

✔ Identify cause of failure, re-

place fuse (under the cover).

➨ Adjusting knob at right stop

position (atmosphere, no

vacuum)?

✔ Turn adjusting knob in direc-

tion “+“ (more vacuum).

➨ Filter clogged?

✔ Replace filter.

❑ No aspiration at the VHC,

pipette drips.

➨ Adapter or aspiration tube

defective?

✔ Replace adapter with aspira-

tion tube.

➨ Filter clogged?

✔ Replace filter.

➨ Leak at the bottle head?

✔ Check seals, coupling and

blind cap. Screw in or re-

place if necessary.

➨ No pumping speed of the

pump?

✔ Perform maintenance, re-

place diaphragm and valves

if necessary.

➨ Adjusting knob at right stop

position (atmosphere, no

vacuum)?

✔ Turn adjusting knob in direc-

tion “+“ (more vacuum).

❑ Pressure control device

switches frequently.

➨ Leak in the system?

✔ Check tubing, seals, coupling,

and blind cap. Screw in or

replace if necessary.

➨ Filter clogged?

✔ Replace filter.

➨ Diaphragms or valves of the

pump defective?

✔ Perform maintenance, re-

place diaphragm and valves

if necessary.

❑ Pump is running continu-

ously.

➨ Leak in the system?

✔ Check tubing, seals, coupling,

and blind cap. Screw in or

replace if necessary.

➨ Pressure control device de-

fective?

✔ Contact your local distributor.

➨ Adjusting knob at left stop

position or close to it (vacuum

demand below ultimate

vacuum of the pump)?

✔ Turn the adjusting knob to

the right in direction “-“ (less

vacuum).

A

service manual with exploded view drawings, spare part lists and directions for

repair is available on request (only in German or English).

The service manual is for trained service people.

NOTICE