Mounting the cover hood, Replacing the fuse – VACUUBRAND BVC 21 NT VARIO User Manual

Page 25

Advertising
background image

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check carefully

the validity of this document with respect to his product. Manual-no.: 999157 / 10/12/2009

page 25 of 31

fuse carrier

Position cover hood on the pump.

Pay attention that the metallic rear panel runs without can-

ting in the slots of the cover hood. Slide on cover hood

completely.

Do not cant the cover at the ducts of the quick coupling or

the adjusting knob.

Use a Hex key size 2.5 to screw in the 4 securing screws

of the cover on the rear side.

Tilt device carefully onto the left side.

Use a Torx screw driver TX 20 to screw in the 4 securing

screws of the cover.

Mounting the cover hood

Move the variable speed drive in the slots of the base plate

to the front until the axis of the adjusting knob protrudes

the cover hood.

Attach the adjusting knob of the vacuum control onto the

axis.

Position the variable speed drive in the slots of the base

plate so that the adjusting knob turns without touching the

cover.

Tighten the two socket head screws again.

Put device back to normal operating position.

Couple hose between collecting bottle and pump at the

quick coupling. Put bottle back in holder.

In case the diaphragm and the valves have been replaced, a run-in period of

several hours is required before the pump achieves its ultimate vacuum.

If the pump does not achieve the ultimate vacuum:

BVC 21 NT VARIO: variable switch-off point, ultimate vacuum is reached with adjust-

ing knob turned completely to the left.

BVC 21 NT: pump is switched off automatically before reaching its ultimate vacu-

um.

If the specified ultimate vacuum is not achieved or if the BVC 21 NT does not reach

its switching point and if this does not change after the run-in period:

Check hose connectors at pump head for leaks. If necessary recheck pump cham-

ber.

Replacing the internal fuse (BVC 21 NT VARIO)

Isolate equipment from mains, remove cover hood (see

section ”Replacing diaphragm and valves”). Open fuse

carrier and replace fuse.

BVC 21 NT VARIO:

Loosen the two socket head screws holding the variable

speed drive slightly (half a turn).

Attention: Don’t undo the socket head screws completely

on any account!