complete the following checklist:

1.

Check oil level, refill with proper grade oil.

2.

Check for loose bolts or hardware.

3.

Check tire pressure. (35 psi)

4.

Trailer level to within 15 degrees.

5.

Battery securely fastened, connections clean

and tight, and proper fluid level.

6.

Fuel tank filled with the proper grade of diesel

fuel.

7.

Check the air cleaner. Service only when

indicated. Do not over service.

B. STARTING INSTRUCTIONS

CAUTION: EQUIPMENT DAMAGE

DO NOT USE STARTING FLUIDS! Immediate engine
damage may result!

Note: This unit is equipped with engine safety shutdown
monitoring of low oil pressure. This shutdown is not
bypassed during start up. The engine will build suffi-
cient oil pressure during cranking to open the safety
switch.

YLT6010DE

1. Depress the fuel pump primer switch for 10

seconds. This will charge the fuel system before
cranking.

2. Turn the Selector Switch to the “START” posi-

tion. The starter will engage and the engine will start.
The Selector Switch is spring loaded so it can’t be
accidentally left in the “START” position. Releasing the
switch in the “START” position will automatically return
it to the “RUN” position.

3. Allow the engine to stabilize in speed and warm

up, then turn on the lights or other external loads
plugged into the receptacles.

4. When stopping the unit, first turn off the lights

and disconnect the external loads. Allow the engine to
cool down at no load for 5 minutes. Then turn the
selector switch to the OFF position.

LLT6012DE

1. If the temperature is below 14 degreees F. Put

the control switch in the run position. Depress the
preheat switch for 15 to 20 seconds. Continuing to
depress the preheat switch move, the selector switch to
the start postion.

Release both switches when the unit starts.

2. If the temperature is above 14 degrees F. turn

the Selector Switch to the “START” position. The starter
will engage and the engine will start. The Selector
Switch is spring loaded so it can’t be accidentally left in
the “START” position. Releasing the switch in the
“START” position will automatically return it to the
“RUN” position.

3. Allow the engine to stabilize in speed and warm

up, then turn on the lights or other external loads
plugged into the receptacles.

4. When stopping the unit, first turn off the lights

and disconnect the external loads. Allow the engine to
cool down at no load for 5 minutes. Then turn the
selector switch to the OFF position.

C.UNIT STORAGE

Certain precautions must be taken if a Mobile Light
System is to be stored for a long period of time. The
unit must be stored in a dry location to prevent the
generator winding from drawing moisture. The unit
should also be thoroughly cleaned prior to storage.

For engine storage procedures, consult your local
Yanmar or Lister engine dealer. They have certain
procedures that must be followed in order to prevent
engine damage, i.e. cylinder rust and injector, injector
pump deterioration.

MAINTENANCE

The ultimate aim of any preventive maintenance pro-
gram is to maintain the equipment in optimum condi-
tion, either in service or ready for service, for the
maximum amount of time during the useful life of the
equipment. The detection of faults before they develop
into major sources of difficulty will decrease the inci-
dence of repair. To this end, a regular schedule of
cleaning and inspection will go far toward assuring
trouble-free operation. Personnel responsible for
maintenance should set up a schedule for inspection,
and cleaning at intervals calculated to keep the equip-
ment in good condition. In making up a schedule, keep
the following in mind:

A. New equipment must be carefully monitored

until extended operation has demonstrated that it is
performing satisfactorily.