Table 12—Model 48N Air Delivery (Cfm) at Indicated External

Static Pressure & Voitage (Sizes 48NLT018 thru 48NHT048)

End Discharge

External Static Pressure-Inches Water

48N

Motor

208V

230V or 460V

Volt/Ph/Hz

Speed

0.0

0.1

0.2

0.3

0.4

0.5

0.0

0.1

0.2

0.3

0.4

0.5

48NLT018,

48NLT024, 48NHT024

A t

Low

712

700

689

680

663

651

750

737

726

716

700

686

208/230-1-60

• t

Med

1185

1129

1088

1026

979

922

1256

1195

1148

1081

1031

971

Hi

1370

1291

1221

1142

1063

1003

1442

1359

1285

1202

1119

1056

48NLT030, 48NMT030

A t

Low

735

726

713

702

689

675

775

763

751

740

726

' 711

208/230-1-60

• t

Med

1184

1163

1150

1134

1105

1064

1248

1226

1211

1194

1164

1120

Hi

1443

1414

1376

1329

1279

1197

1519

1489

1449

1399

1347

1261

48NHT030, LT036

48NMT036, LT042

A t

Low

1002

970

938

898

854

796

1056

1022

986

946

900

839

48NMT042

208/230-1-60

• t

Med

1515

1452

1389

1308

1227

1102

1597

1530

1464

1378

1293

1164-

208/230-3-60, 460-3-60

Hi

1764

1705

1621

1521

1383

1254

1857

1795

1708

1603

1457

1321

48NHT036, NVT036

48NHT042

Л

Low

1610

1570

1504

1435

1358

1260

1787

1733

1641

1559

1458

1345

208/230-1-60
208/230-3-60

Med

1913

1820

1736

1645

1544

1428

1976

1909

1806

1714

1603

1495

460-3-60t

Hi

2032

1942

1844

1759

1636

1514

2086

1983

1883

1782

1665

1545

48NLT048, NMT048

48NHT048

A

Low

1627

1589

1527

1449

1364

1282

1807

1758

1704

1607

1518

1404

208/230-3-60

Med

1945

1880

1796

1708

1611

1508

2061

1970

1892

1813

1704

1580

460-3-60t

Hi

2138

2045

1943

1846

1738

1624

2178

2081

1941

1869

1769

1650

(Applicable notes are listed below Table 13.)

Tabie 13—Down Discharge

External Static Pressure—Inches Water

48N

Motor

208V

230V or 460V

Volt/Ph/Hz

Speed

0.0

0.1

0.2

0.3

0.4

0.5

0.0

0.1

0.2

0.3

0.4

0.5

48NLT018

48NLT024, 48NHT024

АФ

Low

705

692

684

671

657

639

743

730

721

707

693

674

208/230-1-60

• t

Med

1138

1102

1045

996

942

889

1196

1161

1101

1050

993

932

Hi

1308

1234

1162

1084

1020

951

1379

1301

1225

1143

1075

1002

48NLT030, 48NMT030

A t

Low

724

715

706

695

682

665

763

754

744

733

719

701

208/230-1-60

• t

Med

1155

1138

1120

1104

1073

1031

1218

1200

1182

1165

1132

1088

Hi

1411

1362

1326

1249

1195

1133

1493

1457

1412

1358

1274

1218

48NHT030, LT036

48NMT036, LT042,

АФ

Low

969

947

911

863

816

760

1022

998

960

910

860

801

48NMT042

208/230-1-60

• t

Med

1494

1430

1358

1273

1174

1058

1574

1507

1431

1341

1237

1115

208/230-3-60, 460-3-60t

Hi

1683

1615

1536

1440

1274

1153

1763

1700

1619

1492

1343

1215

48NHT036, NVT036
48NHT042, NVT048

A

Low

1534

1493

1430

1359

1280

1200

1704

1638

1553

1468

1390

1304

208/230-1-60
208/230-3-60

Med

1797

1709

1620

1547

1448

1315

1855

1707

1684

1574

1498

1361

460-3-60t

Hi

1885

1779

1704

1608

1507

1404

1906

1821

1722

1623

1533

1410

48NLT048, 48NMT048

48NHT048

208/230-1-60

A

Low

1539

1515

1466

1410

1325

1229

1735

1688

1613

1539

1440

1334

208/230-3-60
208/230-3-60

Med

1833

1768

1700

1599

1505

1390

1918

1849

1752

1670

1561

1442

460-3-60t

Hi

1957

1873

1786

1699

1598

1495

1997

1907

1817

1713

1618

1506

• Factory blower motor speed setting for cooling operation.

AFactory blower motor speed setting for heating operation.

*Air delivery values are without air filter and are for dry coil. See Table 16 for wet coil pressure drop. Deduct field-supplied air filter pressure drop and

wet coil pressure drop to obtain external static pressure available for ducting.

t460 volt units high speed only. Do not change blower speed settings.
tFor 208V operation, change the blower motor speed setting to the next higher speed. See steps 6 and 9.

NOTE: Do not operate the unit at a cooling airflow that is less than 350 cfm per each 12,000 Btuh of rated cooling capacity. Indoor coil icing may occur
at airflows below this point.

16