Table 5—Specifications—Models 48N (Sizes VT042300 thru MT048600)

MODEL

48N

48N

48N

48N

48N

48N

48N

48N

48N

SIZE

VT042300

VT042500

VT042600

LT048300

LT048500

LT048600

MT048300

MT048500

MT048600

Unit Volts—Phase (60 Hz)

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460-3

Operating Voltage Range

187—253

187—253

414—506

187—253

187—253

414—506

187—253

187—253

414—506

Unit Full Load Amps

26.7

18.2

9.6

27.2

22.1

11.0

27.5

22.1

11.0

Maximum Fuse Size (Amps)

45

30

15

50

40

20

50

40

20

Minimum Ampacity for Wire Sizing*

31.7

21.1

11.1

32.7

26.0

13.1

32.7

26.1

13.1

Minimum Wire Size (75 C Copper)

10

12

14

8

10

14

8

10

14

Maximum Wire Length (Ft.)

75

65

110

95

100

100

95

100

100

Cooling Capacity (Btuh)f

41,500

41,500

41,500

47,500

47,500

47,500

47,500

47,500

47,500

Rated Cooling Airflow (cfm)f

1500

1500

1500

1700

1700

1500

1700

1700

1700

External Static Pressure (In.

water)t

0.15

0.15

0.15

0.20

0.20

0.15

0.20

0.20

0.20

ARI Sound Rating^:

8.2

8.2

8.2

8.2

8.2

8.2

8.2

8.2

8.2

Rated Heating Input (cfm)

120,000

120,000

120,000

80,000

80,000

60,000

100,000

100,000

100,000

Output Capacity (Btuh)**

93,000

96,000

96,000

62,000

64,000

48,000

78,000

80,000

80,000

AFUE(%)**

77.5

77.5

77.5

Rated Heating Airflow (cfm)

1367

1367

1367

1481

1481

1481

1481

1481

,1481

Recommended Minimum Field-

Supplied Filter Size (Sq ln.)tt

Disposable-Type

720

816

816

Cleanable- or High-Capacity Type

480

544

544

(Applicable notes are listed below Table 7.)

Table 6—Specifications—Models 48N (Sizes HT048300 thru MT060600)

MODEL

48N

48N

48N

48N

48N

48N

48N

48N

48N

SIZE

HT048300

HT048500

HT048600

LT060300

LT060500

LT060600

MT060300

MT060500

MT060600

Unit Volts—Phase (60 Hz)

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460-3

Operating Voltage Range

187—253

187—253

414—506

187—253

187—253

414—506

187—253

187—253

414—506

Unit Full Load Amps

27.5

22.1

11.0

40.8

31.6

14.6

40.8

31.6

14.6

Maximum Fuse Size (Amps)

50

40

20

60

50

25

60

50

25

Minimum Ampacity for Wire Sizing*

32.7

26.0

13.1

48.5

37.0

17.2

48.5

37.0

17.2

Minimum Wire Size (75 C Copper)

10

12

14

8

10

14

8

10

14

Maximum Wire Length (Ft.)

75

65

110

95

100

100

95

100

100

Cooling Capacity (Btuh)t

47,500

47,500

47,500

59,500

59,500

59,500

59,500

59,500

59,500

Rated Cooling Airflow (cfm)t

1700

1700

1700

2000

2000

2000

2000

2000

2000

External Static Pressure (In.

water)t

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

ARI Sound Ratingf:

8.2

8.2

8.2

8.4

8.4

8.4

8.4

8.4

8.4

Rated Heating input (cfm)

120,000

120,000

120,000

80,000

80,000

80,000

100,000

100,000

100,000

Output Capacity (Btuh)**

93,000

96,000

96,000

62,000

64,000

64,000

78,000

80,000

80,000

AFUE (%)**

77.5

_

77.5

77.5

Rated Heating Airflow (cfm)

1367

1367

1367

1481

1481

1481

1646

1646

1646

Recommended Minimum Field-

Supplied Filter Size (Sq ln.)tt

Disposable-Type

816

960

960

Cleanable- or High-Capacity Type

544

640

640

(Applicable notes are listed below Table 7.)

Table 7—Specifications- - Models 48N (Sizes HT060300 thru HT060600)

MODEL

48N

48N

48N

SIZE

HT060300

HT060500

HT060600

Unit Volts—Phase (60 Hz)

208/230—1

208/230—3

460—3

Operating Voltage Range

187—253

187—253

414—506

Unit Full Load Amps

40.8

31.6

14.6

Maximum Fuse Size (Amps)

60

50

25

Minimum Ampacity for wire Sizing*

48.5

37.0

17.2

Minimum Wire Size (75 C Copper)

10

12

14

Maximum Wire Length (Ft.)

75

65

110

Cooling Capacity (Btuh)t

59,500

59,500

59,500

Rated Cooling Airflow (cfm)t

2000

2000

2000

External Static Pressure (in. water)t

0.20

0.20

0.20

ARI Sound Ratingt

8.4

8.4

8.4

Rated Heating Input (Btuh)**

120,000

120,000

120,000

Output Capacity (Btuh)**

93,000

96,000

96,000

AFUE(%)**

77.5

Rated Heating Airflow (cfm)

1975

1975

1975

Recommended Minimum Field-

Supplied Filter Sizeft

Disposable-Type

960

Cleanable- or High-Capacity Type

640

*lf other than 75 C copper wire is used, determine size from unit ampacity and the National Electrical Code. Voltage drop of wire must be less than 2%

of unit rated voltage.

fRated in accordance with U.S. Government D.O.E. test procedures and/or ARI Standard 210.
tRated in accordance with ARI Standard 270.

**The capacity ratings of single-phase units are in accordance with U.S. Government D.O.E. test procedures and/or A.G.A. certification requirements. For

3-phase units, the efficiency rating is a product thermal efficiency rating determined under continuous operating conditions, independent of any
installed system.

ttRequIred filter areas shown are based on the larger of the ARI-rated cooling airflow or the heating airflow at a velocity of 300 ft/min for disposable type

or 450 ft/mln for hIgh-capacIty type. Air filter pressure drop must not exceed 0.08 in.-water.

8

Advertising