Models 48n (sizes lt042300 thru ht042600) – Carrier 48N User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 2—Specifications—Models 48N (Sizes NLT018300 thru NLT036600)

MODEL

48N

48N

48N

48N

48N

48N

48N

48N

48N

SIZE

LT018300

LT024300

HT024300

LT030300

MT030300

HT030300

LT036300

LT036500

LT036600

Unit Volts—Phase (60 Hz)

208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—3

460—3

Operating Voltage Range

187—253

187—253

187—253

187—253

187—253

187—253

187—253

187—253

414—506

Unit Full Load Amps

11.5

14.2

14.2

16.8

16.8

17.3

21.2

14.6

7.7

Maximum Fuse Size (Amps)

20

25

25

30

30

30

40

25

15

Minimum Ampacity for Wire Sizing*

13.6

17.1

17.1

20.4

20.4

20.7

26.9

18.6

9.0

Minimum Wire Size (75 C Copper)

14

12

12

10

10

10

10

12

14

Maximum Wire Length (Ft.)

60

70

70

100

100

100

75

65

110

Cooling Capacity (Btuh)t

17,800

23,800

23,800

29,000

29,000

29,000

35,200

35,200

35,200

Rated Cooling Airflow (cfm)t

600

800

800

1100

1100

1100

1300

1300

1300

External Static Pressure (In.

water)t

0.10

0.10

0.10

0.15

0.15

0.15

0.15

0.15

0.15

ARI Sound Rating^

7.8

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

Rated Heating Input (cfm)

40,000

40,000

60,000

40,000

60,000

80,000

60,000

60,000

60,000

Output Capacity (Btuh)**

31,000

31,000

46,000

31,000

46,000

61,000

46,000

48,000

48,000

AFUE(%)**

77.5

77.5

77.5

77.5

77.5

77.5

77.5

Rated Heating Airflow (cfm)

658

658

740

658

740

987

987

987

987

Recommended Minimum Field-

Supplied Filter Size (Sq ln.)tt

Disposable-Type

288

384

384

528

624

Cleanable- or High-Capacity Type

192

256

256

352

416

(Applicable notes are listed below Table 4.)

Table 3—Specifications—Models 48N (Sizes MT036300 thru VT036600)

MODEL

48N

48N

48N

48N

48N

48N

48N

48N

48N

SIZE

MT036300

MT036500

MT036600

HT036300

HT036500

HT036600

VT036300

VT036500

VT036600

Unit Volts—Phase (60 Hz)

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460—3

Operating Voltage Range

187—253

187—253

414—506

187—253

187—253

414—506

187—253

187—253

414—506

Unit Full Load Amps

21.2

14.6

7.7

22.4

16.8

8.5 '

22.4

16.8

8.5

Maximum Fuse Size (Amps)

40

25

15

40

25

15

40

25

15

Minimum Ampacity for Wire Sizing*

26.9

18.6

9,0

26.2

19.3

9.8

26.2

19.3

9.8

Minimum Wire Size (75 C Copper)

10

12

14

41

12

12

10

10

10

Maximum Wire Length (Ft.)

75

65

110

60

70

70

100

100

100

Cooling Capacity (Btuh)f

35,200

35,200

35,200

35,800

35,800

35,800

35,800

35,800

35,800

Rated Cooling Airflow (cfm)f

1300

1300

1300

1300

1300

1300

1300

1300

1300

External Static Pressure (In.

water)t

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

ARI Sound Ratingf:

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

Rated Heating Input (cfm)

80,000

80,000

80,00

100,0000

100,000

100,000

120,000

120,000

120,000

Output Capacity (Btuh)**

61,000

64,000

64,000

78,000

80,000

80,000

93,000

96,000

96,000

AFUE(%)**

77.5

__

77.5

77.5

Rated Heating Airflow (cfm)

987

987

987

1481

1481

1481

1367

1367

1367

Recommended Minimum Field-

Supplied Filter Size (Sq ln.)tt

Disposable-Type

624

624

Cleanable- or High-Capacity Type

416

416

(Applicable notes are listed below Table 4.)

Table 4—Specifications- - Models 48N (Sizes LT042300 thru HT042600)

MODEL

48N

48N

48N

48N

48N

48N

48N

48N

48N

SIZE

LT042300

LT042500

LT042600

MT042300

MT042500

MT042600

HT042300

HT042500

HT042600

Unit Volts—Phase (60 Hz)

208/230—1 208/230—1

460—3

208/230—1 208/230—3

460—3

208/230—1 208/230—3

460—3

Operating Voltage Range

187—253

187—253

414—506

187—253

187—253

414—506

187—253

187—253

414—506

Unit Full Load Amps

24.6

16.0

8.8

24.6

16.0

8.8

26.7

18.2

9.6

Maximum Fuse Size (Amps)

50

30

15

50

30

15

45

30

15

Minimum Ampacity for Wire Sizing*

31.1

20.4

10.3

31.1

2.4

10.3

31.7

21.1

11.1

Minimum Wire Size (75 C Copper)

8

10

14

8

10

14

10

12

14

Maximum Wire Length (Ft.)

95

100

100

95

100

100

75

65

110

Cooling Capacity (Btuh)t

41,500

41,500

41,500

41,500

41,500

41,500

41,500

41,500

41,500

Rated Cooling Airflow (cfm)f

1500

1500

1500

1500

1500

1500

1500

1500

1500

External Static Pressure (In.

water)t

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

ARI Sound Rating^:

7.8

8.0

8.0

8.0

8.0

8.0

8.2

8.2

8.2

Rated Heating Input (cfm)

60,000

60,000

60,00

80,000

80,000

80,000

100,000

100,000

100,000

Output Capacity (Btuh)**

46,000

48,000

48,000

61,000

64,000

64,000

78,000

80,000

80,000

AFUE(%)**

77.5

77.5

-

_

77.5

Rated Heating Airflow (cfm)

987

987

987

987

987

987

1481

1481

1481

Recommended Minimum Field-

Supplied Filter Size (Sq ln.)ft

Disposable-Type

720

720

Cleanable- or High-Capacity Type

480

480

*lf other than 75 C copper wire is used, determine size from unit ampacity and the National Electrical Code. Voltage drop of wire must be less than 2%

of unit rated voltage.

tRated in accordance with U.S. Government D.O.E. test procedures and/or ARI Standard 210.
tRated in accordance with ARI Standard 270.

**The capacity ratings of single-phase units are in accordance with U.S. Government D.O.E. test procedures and/or A.G.A. certification requirements. For

3-phase units, the efficiency rating is a product thermal efficiency rating determined under continuous operating conditions, independent of any

installed system.

ttRequired filter areas shown are based on the larger of the ARI-rated cooling airflow or the heating airflow at a velocity of 300 ft/min for disposable type

or 450 ft/min for high-capacity type. Air filter pressure drop must not exceed 0.08 in.-water.