Caution – Cres Cor CCBC-4-35 User Manual

Page 13

Advertising
background image


[ Section 2-Installation ] [ Page 11 ]


C. Removing Plastic Film

Stainless steel surfaces are protected with plastic film when shipped. The film is easily removed
by grasping an edge corner of the film and pulling it off.

D. Locating Your new Blast Chill Unit
The cabinet should not be placed in the immediate vicinity of ranges, ovens and other heat
radiating equipment. This will help to increase efficiency as well as lower operating costs. Self-
contained refrigeration is standard on reach-in chillers. Adequate air ventilation is mandatory
for the condensing unit in order to operate efficiently and to prevent excessive and damaging
operating temperatures. The Blast Chiller should be in an ambient room temperature of 85° or
less.

E. Leveling
The cabinet must be standing level on all four casters for the self-closing doors to operate
properly and for proper drainage of condensation from the evaporator. Casters are non-
adjustable, therefore the floor must be level.

F. Cleaning (refer to section 4)

G. Electrical Supply
All models (except the CCBC12-UA-100) are furnished with an electrical power cord & NEMA
plug, merely requiring that the appropriate NEMA receptacle is available at the installation
location. Model CCBC12-UA-100 requires a qualified electrician to furnish and install wiring
for the power supply. This must be connected to the identified terminals provided inside the
control panel. Refer to the appropriate wiring diagram furnished with the cabinet for guidance.
Electrical power of the current voltage, phase and ampacity must be supplied to the Blast Chiller.
The Chiller must have its own separate electrical circuit breaker with no other equipment or
appliance connected to that breaker. (Dedicated Circuit) See the cabinet data plate located on the
interior wall for the electrical requirements.

CHECK LIST (WITH POWER TURNED OFF)

*****

EXAMINE THE FOLLOWING BEFORE START-UP!

*****

CAUTION:

Make sure the power to chiller is turned off prior to making

these checks to avoid the possibility of unexpected injury !!!

1.

Check that above installation recommendations have been adhered to. Pay particular
attention to installation location for any potential excessive heat sources (oven, range,
etc.) or inadequate air ventilation conditions which can cause compressor overheating
problems and/or failure. If any such condition exists notify the owner to have the installer
correct before continuing.


2.

Check refrigeration tubing for damage and that they are not touching or rubbing against
anything.

(continued)

Advertising
This manual is related to the following products: