[ Section 5- Troubleshooting ]

[ Page 19a ]


ALARM CODES


7-Segment Display

The left hand window shows the cabinet wall temperature.
The right hand displays show the probe temperatures during a blast cycle, and are normally blank
during store. If a probe fails it will indicate pf (probe failure) during a blast.
Cab temp window also acts as a count up timer in probe blast.

If there is an alarm condition, the top probe display will show an alarm number a0 to a7
during store (see table below), but will still show the probe temperature during blast.




7-Seg

Display

Alarm Condition


a0

AIR

ON

SENSOR

FAILURE

a1

WALL

SENSOR

FAILURE

a2

FIN SENSOR FAILURE

a3

FOOD

PROBE

1

FAILURE

*

a4

FOOD

PROBE

2

FAILURE

a5

FOOD

PROBE

3

FAILURE

a6

SPARE

a7

POWER

CUT

DETECTED


* (Top Display On Front Panel Used For 3 Probe Systems)


Note: for each probe only one audible alarm and alarm printout is allowed to be issued
each day. This is to prevent excessive paper use and noise nuisance in the event of an
intermittent probe failure. However, repeated probe failures are displayed on the probe
display window, (top window in the case of 3 probe panels)