TROUBLESHOOTING

Problem

Possible Cause

Solution

Burners will not light

using the ignitor

Burners not assembled cor­

rectly

See Step 9 - Install Burners of the Assembly Instructions

Not pausing long enough
before clicking the control

panel knob

When lighting the 1st (Leftmost) Burner, push-in and turn con­
trol panel knob counter-clockwise until you feel resistance with
turning. Pause 4 seconds with knob still pushed in, then contin­
ue turning knob counter-clockwise until a click is heard

No spark

Gas collector tab is bent (making too large or small of a gap
between electrode and tab). By hand, bend gas collector tab
back within a maximum of 3/16” gap to electrode. (See page 19

for illustration).

LP gas cylinder is empty

Take LP gas cylinder to licensed LP gas supplier to be refilled

Coupling nut is not fully con­
nected to regulator

Tighten coupling nut by hand about one-half to three quarters
additional turn. Do not use tools.

Excess flow valve tripped in

regulator

Turn control knobs to “off position and turn LP gas cylinder

handle clockwise until it stops. Wait five minutes. Relight LP

gas grill.

Obstructions in burners

Clean burners (See Burner Maintenance in Care and
Maintenance section of this manual)

Electrodes and burners are

wet

Dry electrode with clean cloth

Wire is loose or disconnected

Reconnect the wire

Wire is shorting (sparking
between ignitor and elec­

trode)

Replace ignitor wire/electrode assembly (Call the Customer

Service Department)

Burners will not light
using a match

Burners not assembled cor­

rectly

See Step 9 - install Burners page of the Assembly instructions

LP gas cylinder is empty

Take LP gas cylinder to licensed LP gas supplier to be refilled

Excess flow valve tripped in

regulator

Turn control knobs to “off position and turn LP gas cylinder
handle clockwise until it stops. Wait five minutes. Relight LP
gas grill.

Coupling nut is not fully con­
nected to regulator

Tighten coupling nut by hand about one-half to three quarters

Obstructions in burners

Clean burners (See Burner Maintenance in Care and
Maintenance section of this manual)

Low flame or low heat

Gas in LP cylinder Is low

Check LP gas cylinder. Refill if necessary.

Excess flow valve tripped in
regulator

Turn control knobs to “off position and turn LP gas cylinder
handle clockwise until it stops. Wait five minutes. Relight LP
gas grill. If flame remains to be low, turn off gas at cylinder and
grill. Disconnect the regulator from the LP gas cylinder.
Reconnect the regulator to the LP gas cylinder. Perform a leak

test. Relight grill. This will reset the excess flow valve.

n.'i

Advertising