FIG. 4

COMMISSiONiNG

LIGHTING THE BURNER - (Fig. 4)

CAUTION: NO SMOKING OR NAKED LIGHTS

Open the burner outer door to expose the gas control combination valve.

CAUTION: BEFORE LIGHTING ENSURE THAT THE GAS VALVE KNOB 2 IS SET IN THE OFF POSITION.
(SEE FIG. A) AND THE ELECTRICAL SUPPLY TO THE AGA IS SWITCHED ON.

1. Turn off union gas cock 1. Test the gas installation from the meter oook for soundness and purge,

2. Turn on gas supply to cooker and open gas cock 1. 3. Turn the gas valve control knob 2 anti-clockwise to the

position {see Fig. BV Press down and hold the knob in the position while depressing the piezo lighter 3 several

times until the pilot has lit. This can be observed through the viewing window 4.

4. When the pilot has lit continue to hold the gas valve control knob for approximately 30 seconds. If it goes out,
wait 3 minutes and repeat the procedure holding for a little longer.

5. When the pilot flame established, rotate the gas valve control knob 2 anti-clockwise to its low fire position (see
fig, cy Where upon the main burner will automatically light. Leave in the low fire position for at least 30 minutes.