TERMINAL POSITION

1. The range must be installed so that the vent terminal is exposed to the external air and terminal

clearance comply with:
In U.S.: The National Fuel Gas Codes ANSI Z223 1 latest edition Section 7,7.

In Canada: CAN/CGA--B149 installation code.

2. Termination should be on a clear expanse of wall, the terminal being preferably not less than
355mm (14in) away from a corner, recess of projeotion.

3. A hole must be cut through an outside wall with the hole falling 1.5" from inside to outside face of

wall.

Openings in the walls behind or on the floor obelow the appliance must be sealed using the closure plate and
sealant provided.

DO NOT install the terminal under the following conditions;

(a) Within 300mm (12in) measured vertically from the bottom of an openable window, air vent or any
other ventilating opening.

(b) Within 300mm (12in) above adjacent ground level.

(c) Within 600mm (24in) of any surface facing the terminal.

(d) Within 355mm (14in) (U.S.) or 300mm (12in) (Canada) below eaves or balcony.

The terminal must be protected by the terminal protective guard (supplied) installed over the terminal to prevent

unauthorised contact with the hot terminal surfaces. (See Fig. 1).

Technical Specification

Models

GC and GE

GC and GE

Gas Type

Natural Gas

LP.G

Range Model

GC

GE

GC

G

Main Burner injector

400

400

180

1i

Pilot Burner Injector

4212

4212

4208

42

Combination Gas Valve

Bypass Screw

1.20 mm

1.20 mm

0.80 mm

0.80

Gas Burner Pressure

4.0

(inch w.g.)

4.0

(inch w.g.)

10.0

(inch w.g.)

1C

(inch

Combination Gas Valve

S.l.T. EUROSIT

Pilot Assembly

JOHNSONS