WALL TILING

If the cooker is to stand in a reoess or against a wall which is to be tiled, in no circumstances should the tiles

overlap the range top plate.

GAS SUPPLY - U.S. PIPE THREADS

NOTE- A MANUAL VALVE MUST BE INSTALLED IN AN ACCESSIBLE LOCATION IN THE GAS PIPE
EXTERNAL TO THE APPLIANCE FOR THE PURPOSE OF TURNING ON OR SHUTTING OF GAS TO THE

APPLIANCE .

ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.

Maximum Heat Input: 4,4kW (15,000 Btu/h)

The maximum gas inlet pressure at the appliance must not exceed 10 inches w.g. for Natural Gas, 14 inches w.g.
for L.P. Gas, The minimum gas inlet pressure at the appliance must be 5 inches w.g. Natural Gas and 11 inches
w.g. L.P. Gas to enable the correct manifold pressure to be obtained.

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system attest pressures in excess of 1/2 psig (3.5kPa), The appliance must be

isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure

testing of the gas supply piping system at test pressure equal to or less than 1/2 psi (3.5kPa).

On completion test the gas installation for soundness and purge. Leak testing of the appliance shall be conducted
according to manufacturer’s instuctions.

NOTE; Use soapy water solution on new gas connections to ensure there are no gas leaks.

AIR SUPPLY

Kitchen or Internal Air Supply

.

. ,

The appliance can only be installed in a room which meets ventilation regulations in force but in any event the

room must have a permanent vent of minimum free air area 36cm

г

(5.Sin 2 ).

In the event of an extractor fan being fitted in the vacinity of the range, compensatory ventilation will be required

to satisfy the demands of the fan without influencing combustion efficiency and flue conditions.

ELECTRICAL

IIO/I2OV6OHZ 10 AMP FLEXIBLE CORD AND PLUG PARALLEL TYPE. The appliance when installed, must be

electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical
Codes ANSI/NFPA 70.

An electrical socket must be provided within 6 feet of the LH side of the appliance and easily accessible to the

user to disconnect. Do not position socket above the appliance.

WARNING

Electrical Grounding Instructions

This appliance is equipped with a (three-prong) grounding plug for your protection against a shock hazard and

should be plugged directly into a proper receptacle. Do not cut or remove the grounding prong from this plug.