3 mmc control operation, Module management controller, 1 overview – ADLINK aTCA-N700 User Manual

Page 36: 2 features, And functions

Advertising
background image

aTCA-RN710 User's Guide

36

• Power

Sequence

9

The MMC controls all the power rail enable/disable signals, which is essential to the

power sequencing. The power sequencing therefore is controlled by the MMC.

• Power

monitoring

9

All the power rail monitoring is done. Any violation of the threshold vales triggers an

event and the MMC reports to the IPMC and shuts down the power to protect the board.

• FRU

Information

9

The MMC provides a Master only I2C Interface which is connected to an EEPROM that

contains RTM information, the log, and the alarms.

• Sensor

9

The on board sensors are connected to a Master only I2C Interface of the MMC and

provide the collected information such as voltage and thermal values to the MMC per the
MMC’s request.

7.3 MMC Control Operation

Some of the major chassis management operations are described in Table 7-1 and detailed
explanations follow.


Table 7-1 Board Shutdown and Reset Procedures (Front Blade + RTM)

No

Item

Description

1

Cold Reset

Cold reset Command from Shelf manager

2

Front Blade Deactivate Front Blade Deactivate Command from Shelf

manager

3

Front Blade Activate

Front Blade activate Command from Shelf
manager

4

RTM Deactivate

RTM Deactivate Command from Shelf manager

5

RTM Activate

RTM activate Command from Shelf manager

6

Front blade shutdown

Front Blade Shutdown Command from LMP

7

RTM shutdown

RTM Shutdown Command from LMP

8

Front Hot swap

Open the Hot-swap switch of Front blade

9

RTM Hot swap

Open the Hot-swap switch of RTM



Advertising