4 sensor threshold values, 1 voltage threshold, 2 temperature threshold – ADLINK aTCA-N700 User Manual
Page 44: Table 7-10 signals: rtm hot swap procedure, 4 sensor threshold values 7.4.1
aTCA-RN710 User's Guide
44
7.4 Sensor Threshold Values
7.4.1
Voltage Threshold
The voltage monitoring sensors are installed as summarized in Table 7-11.
Table 7-11 Sensor Voltage Threshold
Title
Thresholds
Hysteresis
RTM1 +12V_A
UNR : +15V
UC : +14V
UNC : +12.6V
LNC : +11.4V
LC : +4.5V
LNR : N/A
0.1V
RTM1 +3.3V_MP
UNR : 3.78V
UC : +3.6V
UNC : +3.46V
LNC : 3.135V
LC : +3V
LNR : N/A
0.04V
RTM1 +3.3V
UNR : 3.6V
UC : +3.465V
UNC : N/A
LNC : N/A
LC : +3.135V
LNR : N/A
0.04V
7.4.2
Temperature Threshold
The temperature monitoring sensors are installed as in Table 7-12.
Table 7-12 Sensor Temperature Threshold
Title
Thresholds
Hysteresis
RTM1 Inlet Temp
UNR : 70
℃
UC : 60
℃
UNC : 45
℃
2
℃
RTM1 SFP Temp
UNR : Tmax -
△T + 10℃
UC : Tmax -
△T
UNC : Tmax -
△T - 10℃
2
℃