Table 7-2 signals: cold reset procedure – ADLINK aTCA-N700 User Manual

Page 38

Advertising
background image

aTCA-RN710 User's Guide

38

„

Deactivate

Dea

c

tiva

te Done

De

ac

ti

va

te

CMD

Power OFF

Deactivate CMD

IPMC

LMP

UART#1

Power

Sequence

P5(4)

P5(5)

PAYLO

D

I

nterfac

e

Figure 7-3 Deactivate Procedure

Shelf manager sends Deactivate to IPMC.

IPMC sends Deactivate to LMP via PAYLOAD Interface (UART).

LMP completes the operation and sends the completion message via PAYLOAD Interface

(UART) to IPMC.

IPMC initiates Power Down sequence to power off Front Blade and RTM.

Table 7-3 Signals: Deactivate Procedure

Signal Name

Status

PAYLOAD Interface
P5(4),P5(5)

Deactivate Command

- IPMI Message

Deactivate Done Indicator

- IPMI Message

„

Activate

Figure 7-4 Activate Procedure

Shelf manager sends Active Command to IPMC.

IPMC initiates Power ON sequence to power ON Front Blade and RTM.

Table 7-4 Signals: Activate Procedure

Signal Name

Status

PAYLOAD Interface
P5(4),P5(5)

Activate Command

- IPMI Message

Deactivate Done Indicator

- IPMI Message