Table 7-6 signals: rtm activate procedure, Ipmc lmp, Atca-rn710 user's guide – ADLINK aTCA-N700 User Manual

Page 41: Shutdown triggered by lmp, Figure 7-7 shutdown procedure, Table 7-7 signals: shutdown procedure, Rtm shutdown triggered by lmp, Figure 7-8 rtm shutdown procedure

Advertising
background image

aTCA-RN710 User's Guide

41

„

Shutdown triggered by LMP

Power OFF

Sh

utd

o

wn

C

M

D

IPMC

LMP

UART#1

Power

Sequence

P5(5)

PAYLOD In

ter

fa

c

e

Figure 7-7 Shutdown Procedure

LMP sends Shutdown Command to IPMC via PAYLOAD Interface (UART).

IPMC initiates Power Down sequence to turn off Blade and RTM power.

Table 7-7 Signals: Shutdown Procedure

Signal Name

Status

PAYLOAD Interface
P5(4),P5(5)

Shutdown Command

- IPMI Message

„

RTM Shutdown triggered by LMP

RT

M

P

o

we

r

OFF

RTM Power

OFF

RTM

Disable

RTM

_

Shutd

o

w

n

C

M

D

IPMC

LMP

MMC

P5(4)

P5(5)

P8(0,1)

RTM DC/DC

PC(0)

RTM

Pow

e

r

OFF Done

PAYLO

A

D

Interface

IPMB-L

PD(0,1)

RTM POWER

RTM SIDE

P1(4)

Figure 7-8 RTM Shutdown Procedure


LMP sends RTM Shutdown to IPMC via PAYLOAD Interface (UART).

IPMC sends RTM Power OFF to MMC via IPMB-L.

MMC completes RTM Power OFF operation and sends the completion message to IPMC.

IPMC turns off RTM Power 12V.

IPMC sends RTM Disable information to LMP via PAYLOAD Interface (UART).