IPMI User Guide

9.5

Communications with IPMC

Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x3E8 and IRQ: 3. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use “COM3” to com-
municate with the IPMC.

9.6

IPMI Sensors List

9.7

Relevant Documents

Sensor

Number

Sensor name

Normal

Reading

Remark

00h

BMC Watchdog

01h

3.3V

3.3 V

02h

5V

5 V

03h

12V

12 V

04h

SYSTEM Temp

25ºC

05h

CPU Temp

40ºC

06h

BIOS CHANGE

07h

BIOS POST ERROR

Document Title

Revision

Source

Intelligent Platform
Management Interface
Specification v2.0

Document Revision 1.1
February 20, 2002

Intel Corp.
http://www.intel.com/design/
servers/ipmi/spec.htm

PICMG 2.9 D1.0
CompactPCI System
Management Specification

January 21, 2000

Intelligent Platform
Management Bus
Communications Protocol
Specification v0.9

Document Revision 0.15
June 24, 1997

Intel Corp.
http://www.intel.com/design/
servers/ipmi/license_ipmi.htm