26

ALPHA PROFILE 800 “ST”

1

2

15

Bearing group replacement - Fig. 15

GOBO ROTATION

086401/001

086402/001

086405/001

085531/001

086406/001

086404/001

GOBO
INDEX

1

2

086403/001

16

17

To determine which side of a godo is coated, hold an odject up to it. On the
uncoated side, there is a space between the object and its reflection.

Grey/Black side

away from lamp

Coated side

towards lamp

Coated side

Uncoated side

Uncoated side

GOBO DI VETRO DICROICI TIPO 1

GOBO DI VETRO DICROICI TIPO 2

Gobo orientation - Fig. 17
The pictures shown the correct gobos orientation.

Replacing rotating gobos (ø 25.7 mm - max 19 mm image – thickness max 1.1 mm) - Fig. 16
IMPORTANT: Use only glass gobos on the rotating gobos wheels.
WARNING: Before using personalised gobos contact Clay Paky.