Clay Paky ALPHA PROFILE 800 “ST” User Manual

Page 40

Advertising
background image

40

ALPHA PROFILE 800 “ST”

• FUNCTION - channel: 35

BIT

EFFECT

255

51-62

38-50

0-37

LINEAR (Default)

UNUSED RANGE

UNUSED RANGE

63

CONVENTIONAL

DIMMER CURVE
FUNCTION

The functions are actived passing through unused range and staying 5 seconds in
necessary level.

• TILT FINE - channel 34

Operation with option Invert Tilt

G

Off

(Pan conventionally represented at 0 bit and option Invert Pan

G

Off)

BIT

255

0

Operation with option Invert Tilt

G

On

(Pan conventionally represented at 0 bit and option Invert Pan

G

Off)

• TILT - channel 33

Operation with option Invert Tilt

G

Off

(Pan conventionally represented at 0 bit and option Invert Pan

G

Off)

BIT

255

128

0

Operation with option Invert Tilt

G

On

(Pan conventionally represented at 0 bit and option Invert Pan

G

Off)

BIT

255

128

0

BIT

255

0

• RESET - channel: 36

BIT

EFFECT

255

128
127

77

76

26

25

0

Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.

COMPLETE RESET
PAN / TILT RESET

PAN / TILT RESET
EFFECTS RESET

EFFECTS RESET

UNUSED RANGE

Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.

Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.

COMPLETE RESET

• LAMP CONTROL (only with option LAMP DMX On) - channel: 37

IMPORTANT: Alpha Profile 800 “ST” is not provided with hot restrike igniter

LAMP ON (FULL POWER)

LAMP ON (FULL POWER)

BIT

EFFECT

255

180

0

101

100

LAMP OFF

179

26

LAMP OFF

25

UNUSED RANGE

Lamp ignition after 5 s
in full power levels.

Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.

UNUSED RANGE

UNUSED RANGE

Immediate transition
from half to full power.

ON

ON

OFF

OFF

The functions are actived passing through unused range and staying 5 seconds in
necessary level.

The functions are actived passing through unused range and staying 5 seconds in
necessary level.

Advertising