Remove debris, Procedure, Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 60

Advertising
background image

FX50 Operator’s Manual

Vacuum and Pothole - 59

Remove Debris

CMW

Remove Debris

Procedure

1.

Position vacuum hose in area to be excavated.

2.

Start engine.

3.

Open inlet valve if necessary to begin excavation.

4.

Use sight glasses to monitor debris level in tank. Vacuum will shut off when tank is full but always heed
trailer and tank lifting capacities as indicated on page 53. Engine will remain running.

EMERGENCY SHUTDOWN: Turn ignition switch to STOP.

Vacuum will suffocate. Maintain distance between face and

vacuum inlets.

Fire or explosion possible. Do not vacuum flammable or

combustible substances.

Incorrect procedures could result in death, injury, or property

damage. Learn to use equipment correctly.

To help avoid injury: Do not excavate hazardous or toxic materials. Unit is designed to
excavate only soil cuttings, drilling fluids, and other non-toxic waste.

Advertising
This manual is related to the following products: