FX50 Operator’s Manual

Service - 83

10 Hour

CMW

Check Air Filter Indicator and Clean
Dust Trap

Check air filter indicator (2) and inspect dust trap
(1) for cracks every 10 hours. Change filter
elements when indicator reaches red zone.

Check Hydraulic Fluid Level

With frame level, check oil at indicator every 10
hours. Add THF at fill (1) as necessary. Clean dust
from cap by blowing with low-pressure air.

NOTICE: Only open the air filter canister when
air restriction is indicated. Change the elements,
do not attempt to clean them.

Compressed air or water may damage filter
elements.

Tapping filter elements to loosen dirt may
damage filter seals.

j36om007w.eps