500 hour, Vacuum system, Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 98

Advertising
background image

FX50 Operator’s Manual

Service - 97

500 Hour

CMW

500 Hour

Vacuum System

Change Engine Oil and Filter

Change oil and filter every 500 hours.

1.

Drain crankcase through drain (1) while oil is
warm.

2.

Replace filter (2) each time oil is changed.

3.

Add 8 qt (7.5L) of DEO at fill neck (4).

4.

Verify correct oil level at dipstick (3).

Change Fuel Filter

Replace fuel filter (4) and clean filter screen every
500 hours for normal service. See parts manual or
contact your Ditch Witch dealer for correct
replacement filter.

To clean filter screen:

1.

Close fuel shut-off valve.

2.

Unscrew nut (1).

3.

Remove fuel strainer cover (2).

4.

Clean fuel strainer (2) with diesel fuel.
Replace if necessary.

5.

Place seal (3) in position.

6.

Mount fuel strainer cover (2). Tighten screw (1).

7.

Check for leaks.

Location

Task

Notes

Vacuum
System

Change engine oil and filter

DEO

Change fuel filter and clean filter screen

j36om041w.eps

1

2

3

4

j36om042w.eps

1

4

2

3

Advertising