Open/close tank door, 300 or 800 tank, Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 67

Advertising
background image

Vacuum and Pothole - 66

FX50 Operator’s Manual

Open/Close Tank Door

CMW

Open/Close Tank Door

300 or 800 Tank:

Open

1.

If tank is tilted, lower tank fully before opening door.

2.

Open tank inlet valve.

3.

Set hydraulic function switch to door position.

4.

Press OPEN on tethered control.

Close

1.

Press CLOSE on tethered control until the linkage on both sides of the tank is fully collapsed.

2.

Close tank inlet valve.

Crushing weight could cause death or serious injury. Use proper

procedures and equipment or stay away.

To help avoid injury: Use tools (provided with unit) if unit must be serviced with tank
door up.

To help avoid injury: Do not raise tank with door held closed only by vacuum. Door may suddenly
open and possibly injure someone.

NOTICE: Do not drive with tank or door raised.

IMPORTANT: Depressurize tank before emptying cyclonic canister, cleaning filter, clearing hoses or
opening any doors.

Advertising
This manual is related to the following products: