Sk350 operator’s manual – Ditch Witch SK350 User Manual
Page 54
SK350 Operator’s Manual
Service - 53
10 Hour
CMW
Check Hydraulic Hoses
Check hydraulic hoses for leaks every 10 hours.
Fluid or air pressure could pierce skin and cause injury or
death. Stay away.
NOTICE:
•
Escaping pressurized fluid can cause injury or pierce skin and poison.
•
Before disconnecting a hydraulic line, turn engine off and operate all controls to relieve pressure.
Lower, block, or support any raised component with a hoist. Cover connection with heavy cloth and
loosen connector nut slightly to relieve residual pressure. Catch all fluid in a container.
•
Before using system, check that all connections are tight and all lines are undamaged.
•
Fluid leaks can be hard to detect. Use a piece of cardboard or wood, rather than hands, to search
for leaks.
•
Wear protective clothing, including gloves and eye protection.
•
If you are injured, seek immediate medical attention from a doctor familiar with this type of injury.