Specifications - 68

SK350 Operator’s Manual

Basic Unit

CMW

The rated operating capacity for this machine was determined using a standard bucket in the drive position
with center of gravity x in (x mm) from the mounting plate. Depending on the attachment, the actual
operating capacity of the attachment may vary.

Rated operating capacity (@ 35% of tipping capacity)

The rated operating capacity for this machine was determined using a
standard bucket in the drive position with center of gravity 7 in (178 mm)
from the mounting plate. Depending on the attachment, the actual operating
capacity of the attachment may vary.

350 lb

158 kg

A2

Angle of departure

18°

18°

Swing radius

35 in

889 mm

Performance

U.S.

Metric

Ground drive speed, forward

3.0 mph

4.8 km/h

Ground drive speed, reverse

3.0 mph

4.8 km/h

Ground pressure with no bucket or operator

3.9 psi

0.27 bar

Hydraulic System

U.S.

Metric

Auxiliary:

Flow rate

12 gpm

45.5 L/min

Pressure

2300 psi

158 bar

Ground drive: dual hydrostat

Flow rate

11 gpm

42 L/min

Pressure

2330 psi

162 bar

Power

U.S.

Metric

Engine: Kohler CH20

Cooling medium

air

Number of cylinders

2

Displacement

38 in

3

624 cm

3

Bore

3.03 in

77 mm

Stroke

2.64 in

67 mm

Installed net power per SAE J1349 (@ 3600 rpm)

20 hp

14.9 kW

Maximum governed speed (no load)

3850 rpm

3850 rpm