VENT DAMPER OPERATION

Figure 7

Figure 8

For safe, effi cient operation, vent damper and all fl ue

product carrying areas of appliance must be checked

annually, with particular attention given to deterioration

from corrosion or other sources. If you see corrosion or

other deterioration, contact your heating contractor for

repairs. Check vent damper operation as follows:

• When boiler is off, check vent damper positions

indicator points to closed position. See Figure 9.

• Turn thermostat or controller up to call for heat and

check vent damper indicator points to open position.

See Figure 9.

• Turn thermostat or controller down again and check

damper position indicator returns to closed position.

Vent Damper Manual Operation
Vent damper may be placed in open position to permit

burner operation by using “HOLD DAMPER OPEN” switch,

located on damper controller. Thermostat will control

burner fi ring as before, while damper will remain open. DO

NOT turn damper open manually or motor damage will re-

sult. Set switch to “AUTOMATIC OPERATION” to close vent

damper during burner off cycle.

For further information, and vent damper

troubleshooting guide, refer to manual packaged with

vent damper.
Inspect vent damper at least once a year by a

qualifi ed service technician.