FTXL Hardware Guide

77

Figure 33 shows the signals while writing the downlink data.

Read Status

(Ready)

Write

Length (9)

Read

Status
(Busy)

Read Status

(Ready)

Write Data

(0x52)

Read

Status
(Busy)

Read Status

(Ready)

Write Data

(0x01)

Read

Status
(Busy)

Read Status

(Ready)

Write 0x02, 0x04, 0x08, 0x10,

0x20, 0x40, 0x80. Read status

between each (ready)

Data bytes

Figure 33. Writing the Downlink Data

Note: You can read the data that is being written by looking at the line labeled
D, but because the D0 line switches it function between being a data line and

being the handshake line, be sure to interpret the D line as data only when A0 is
low.
Figure 34 on page 78 shows the signals while reading the uplink data.

Advertising