SDH Tabs

SONET/SDH Application

361

LOP TX (SDH, TU-3 path)

Alarm Generation

Allows Continuous or Burst alarm generation methods.

³

Type: The following errors are available:

TU-AIS (Tributary Unit - Alarm Indication Signal): Generates an all-ones
patterns for the path and payload.

LP-RDI (Low Order Path - Remote Defect Indication): Generates a
“100” pattern for bits 5, 6 and 7 of the G1 byte.

ERDI-SD (Enhanced RDI - Server Defect): Generates a “101” pattern for
the bits 5, 6 and 7 of the G1 byte.

ERDI-CD (Enhanced RDI - Connectivity Defect): Generates a “110”
pattern for the bits 5, 6 and 7 of the G1 byte.

ERDI-PD (Enhanced RDI - Path Payload Defect): Generates a “010”
pattern for the bits 5, 6 and 7 of the G1 byte.

TU-LOP (Tributary Unit - Loss of Pointer): Generates a non-valid
pointer.

LP-UNEQ (Low Order Path - Unequipped): Generates samples of
unequipped signal labels (C2 is set to “00 H”).