10 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 10

Advertising
background image

10

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

CMD

Message Commands and Queries (CMD) Contents

The command can be one of the following values and consists always of 3 bytes in positions 2,3,4:

Byte 2 Byte 3 Byte 4 ASCII Description

I/O

Unit

Type

Page

0x42

0x52

0x49

"BRI"

Backlight Minimum Value

W

all

12

0x42

0x52

0x4C

"BRL" Set LED Glass Display Control™ (GDC) Brightness

R/W

xxC

12

0x42

0x52

0x4D

"BRM" Backlight Maximum Value

W

all

12

0x42

0x52

0x54

"BRT" User Brightness Control

W

all

13

0x42

0x52

0x55

"BRU" Glass Display Control™ (GDC) Brilliance Button

W

xxC

13

0x42

0x5A

0x5A

"BZZ"

Buzzer Control

W

all

14

0x44

0x4C

0x3F

"DL?"

Query available ECDIS packages

R

all

14-15

0x44

0x4C

0x4E

"DLN" Download ECDIS package table x

R

all

15

0x45

0x54

0x43

"ETC" Elapsed Time Counter Query

R

all

17

0x46

0x48

0x41

"FHA" Feature Header (Potentiometer)

W

xxD

17

0x46

0x57

0x56

"FWV" Firmware Version Video chipset, Cypress and Ethernet

controller

R

xxD

18

0x47

0x4D

0x42

"GMB" Set LED Glass Display Control™ (GDC)

Minimum Brightness

W

all

18

0x49

0x4E

0x56

"INV"

Flip image upside down (12 and 15 inch units only)

W

xxD

18

0x4C

0x49

0x53

"LIS"

Luminance and Environment Sensor Measurement

R

all

19

0x4D

0x41

0x4E

"MAN" Manufacturer ID Code

R

xxD

19

0x50

0x4F

0x54

"POT" Potentiometer Control

W

all

20

0x53

0x4E

0x42

"SNB" Serial Number Query

R

all

20

0x53

0x57

0x49

"SWI"

Main Software (Video Controller) Version Query

R

all

21

0x53

0x57

0x4B

"SWK" Glass Display Control™ (GDC) software version Query

R

xxC

21

0x54

0x4D

0x50

"TMP" Temperature Sensor Query

R

xxD

21

0x54

0x59

0x50

"TYP" Type/Model Number Query

R

all

22

0x51

0x44

0x55

"QDU" QM57 Chipset Duplex Mode

W

xxC

22

0x4D

0x43

0x43

"MCC" OSD Control Functionality*

with key global commands:

"?" = Query OSD value

"R" = Reset OSD value

"r" = Reset OSD value

"+" = Increase OSD value

"-" = Decrease OSD value

R/W

xxD

23-33

Notes:

I/O

= R=Read, W=Write.

Unit Type

= xxD = MMD/STD, xxC = MMC units, all = MMD/STD/MMC

Page #

= Page number in this manual where command is detailed.

* "MCC

= command is not supported on Maritime Multi Computer (MMC) units, due to no OSD menu

available. The "MCC" command also features a Query "?" mode, "R" or "r" reset mode to factory

default, increase +1 from current value "+" and decrease -1 from current value "-". Details and

usage of these commands are available later in this manual.

NOTE: Due to firmware revisions, some commands listed above will not be available on earlier units.

Advertising