30 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 30

Advertising
background image

30

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

MCC Command

Syntax and Functionality

Details and Values

Set IP Address (fixed or auto)

Note:

By sending this command, the

communication mode will be

automatically set to "Ethernet",

in the

"Communication Mode"

,

referenced earlier in this chapter.

In addition, a power off/on to

the unit is required to reboot the

internal network code and utilize

the newly set IP address. This

can either be done by issue the

"Power down / up"

command

described earlier in this table or

do a physical power off/on for

the unit.

This command is not available

on STD units.

Syntax : 07 FF 4D 43 43 10 16

BC

v1 v2 v3

2E

w1

W2 W3

2E

x1 x2 x3

2E

y1 y2 y3

zz

Function Examples:
Example fixed IP 192.168.1.35, Send:"192.168.001.035":
07 FF 4D 43 43 10 16

BC

31 39 32

2E

31 36 38

2E

30 30

31

2E

30 33 35

55

Set Auto IP "A" : 07 FF 4D 43 43 02 24

BC

41

02

Set Auto IP "a" : 07 FF 4D 43 43 02 24

BC

61

E2

Where

v1

= "0" to "2"

Where

v2

= "0" to "9"

Where

v3

= "0" to "9"

Where

w1

= "0" to "2"

Where

w2

= "0" to "9"

Where

w3

= "0" to "9"

Where

x1

= "0" to "2"

Where

x2

= "0" to "9"

Where

x3

= "0" to "9"

Where

y1

= "0" to "2"

Where

y2

= "0" to "9"

Where

y3

= "0" to "9"

Where 2E = "." (dot)

Where

zz

= Calculated Checksum

or

Where

v1

= "a" or "A" (Auto IP)

Where

zz

= Calculated Checksum

Available response status:

"0" = Fail

"1" = Successful

Auto Position

Note:

PC mode only.

Send Only : 07 FF 4D 43 43 01 25

C3

3C

Available response status:

"0" = Fail

"1" = Successful

Auto Color Balance

Send Only : 07 FF 4D 43 43 01 25

C5

3A

Available response status:

"0" = Fail

"1" = Successful

OSD Outdoor Mode

Syntax : 07 FF 4D 43 43 02 24

CA

xx

zz

Function Examples:
Example "1" : 07 FF 4D 43 43 02 24

CA

31

04

Where

xx

= "0" to "1"

Where

zz

= Calculated Checksum

Available functions:

"0" = No delay for all touch

buttons, except 2 sec delay

for "MENU"

"1" = Delay 5 seconds for all touch

buttons

Burn In

Syntax : 07 FF 4D 43 43 02 24

CC

xx

zz

Function Examples:
Example "1" : 07 FF 4D 43 43 02 24

CC

39

0B

Query "?" : 07 FF 4D 43 43 02 24

CC

3F

F4

Reset "R" : 07 FF 4D 43 43 02 24

CC

52

E1

Reset "r" : 07 FF 4D 43 43 02 24

CC

72

C1

Where

xx

= "0" to "1"

Where

zz

= Calculated Checksum

Available functions:

"0" = Normal Mode

"1" = Burin In Mode

Test Pattern

Syntax : 07 FF 4D 43 43 02 24

CD

xx

zz

Function Examples:
Example "1" : 07 FF 4D 43 43 02 24

CD

31

01

Where

xx

= "0" to "1"

Where

zz

= Calculated Checksum

Available functions:

"0" = Normal Display

"1" = Display built-in Test Pattern

Reset Factory Default

Send Only : 07 FF 4D 43 43 01 25

CE

31

Available response status:

"0" = fail

"1" = successful

Save User Default

Note:

Available function list differs

between MMD and STD units!

Syntax : 07 FF 4D 43 43 02 24

D7

xx

zz

Function Examples:
Example "3" : 07 FF 4D 43 43 02 24

D7

33

F5

Where

xx

= "1" to "5"

Where

zz

= Calculated Checksum

Available functions (MMD):

"1" = User1 Slot

"2" = User2 Slot

"3" = User3 Slot

"4" = User4 Slot

"5" = User5 Slot

Available functions (STD):

"1" = User Slot

Available response status:

"0" = Fail

"1" = Successful

Advertising