28 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 28

Advertising
background image

28

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

MCC Command

Syntax and Functionality

Details and Values

PIP, PBP Contrast Control

Syntax : 07 FF 4D 43 43 03 23

A3

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

A3

35 30

F7

Query "?" : 07 FF 4D 43 43 02 24

A3

3F

1D

Reset "R" : 07 FF 4D 43 43 02 24

A3

52

0A

Reset "r" : 07 FF 4D 43 43 02 24

A3

72

EA

Increase "+" : 07 FF 4D 43 43 02 24

A3

2B

31

Decrease "-" : 07 FF 4D 43 43 02 24

A3

2D

2F

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "3" "2"

PIP Horizontal Position

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 03 23

A4

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

A4

35 30

F6

Query "?" : 07 FF 4D 43 43 02 24

A4

3F

1C

Reset "R" : 07 FF 4D 43 43 02 24

A4

52

09

Reset "r" : 07 FF 4D 43 43 02 24

A4

72

E9

Increase "+" : 07 FF 4D 43 43 02 24

A4

2B

30

Decrease "-" : 07 FF 4D 43 43 02 24

A4

2D

2E

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "6" "4"

PIP Vertical Position

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 03 23

A5

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

A5

35 30

F5

Query "?" : 07 FF 4D 43 43 02 24

A5

3F

1B

Reset "R" : 07 FF 4D 43 43 02 24

A5

52

08

Reset "r" : 07 FF 4D 43 43 02 24

A5

72

E8

Increase "+" : 07 FF 4D 43 43 02 24

A5

2B

2F

Decrease "-" : 07 FF 4D 43 43 02 24

A5

2D

2D

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "6" "4"

PIP Window Size Select

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 02 24

A6

xx

zz

Function Examples:
Example "4" : 07 FF 4D 43 43 02 24

A6

34

25

Query "?" : 07 FF 4D 43 43 02 24

A6

3F

1A

Reset "R" : 07 FF 4D 43 43 02 24

A6

52

07

Reset "r" : 07 FF 4D 43 43 02 24

A6

72

E7

Increase "+" : 07 FF 4D 43 43 02 24

A6

2B

2E

Decrease "-" : 07 FF 4D 43 43 02 24

A6

2D

2C

Where

xx

= "1" to "7"

Where

zz

= Calculated Checksum

Default: "7"

Second Source Select

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 02 24

A7

xx

zz

Function Examples:
Example "4" : 07 FF 4D 43 43 02 24

A7

34

24

Query "?" : 07 FF 4D 43 43 02 24

A7

3F

19

Reset "R" : 07 FF 4D 43 43 02 24

A7

52

06

Reset "r" : 07 FF 4D 43 43 02 24

A7

72

E6

Where

xx

= "0" to "6"

Where

zz

= Calculated Checksum

Available functions:

"0" = Digital 1 (default)

"1" = Digital 2

"2" = Analog RGB1

"3" = Analog RGB2

"4" = Composite 1

"5" = Composite 2

"6" = Composite 3

Color Temperature Select

Syntax : 07 FF 4D 43 43 02 24

B3

xx

zz

Function Examples:
Example "2" : 07 FF 4D 43 43 02 24

B3

32

1A

Query "?" : 07 FF 4D 43 43 02 24

B3

3F

0D

Reset "R" : 07 FF 4D 43 43 02 24

B3

52

FA

Reset "r" : 07 FF 4D 43 43 02 24

B3

72

DA

Where

xx

= "0" to "3"

Where

zz

= Calculated Checksum

Available functions:

"0" = 9300K

"1" = 8000K (default)

"2" = 6500K

"3" = USER

Examples on Response:

"8" "0" "0" "0" (8000k)

"U" "S" "E" "R" (USER)

Red Level for Selected Color

Temperature

Note:

Available function list differs

between MMD and STD units!

Syntax : 07 FF 4D 43 43 03 23

B4

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

B4

35 30

E6

Query "?" : 07 FF 4D 43 43 02 24

B4

3F

0C

Reset "R" : 07 FF 4D 43 43 02 24

B4

52

F9

Reset "r" : 07 FF 4D 43 43 02 24

B4

72

D9

Increase "+" : 07 FF 4D 43 43 02 24

B4

2B

20

Decrease "-" : 07 FF 4D 43 43 02 24

B4

2D

1E

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default MMD: "3" "2"

Default STD: "6" "4"