29 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 29

Advertising
background image

29

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

MCC Command

Syntax and Functionality

Details and Values

Green Level for Selected Color

Temperature

Note:

Available function list differs

between MMD and STD units!

Syntax : 07 FF 4D 43 43 03 23

B5

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

B5

35 30

E5

Query "?" : 07 FF 4D 43 43 02 24

B5

3F

0B

Reset "R" : 07 FF 4D 43 43 02 24

B5

52

F8

Reset "r" : 07 FF 4D 43 43 02 24

B5

72

D8

Increase "+" : 07 FF 4D 43 43 02 24

B5

2B

1F

Decrease "-" : 07 FF 4D 43 43 02 24

B5

2D

1D

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default MMD: "3" "2"

Default STD: "6" "4"

Blue Level for Selected Color

Temperature

Note:

Available function list differs

between MMD and STD units!

Syntax : 07 FF 4D 43 43 03 23

B6

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

B6

35 30

E4

Query "?" : 07 FF 4D 43 43 02 24

B6

3F

0A

Reset "R" : 07 FF 4D 43 43 02 24

B6

52

F7

Reset "r" : 07 FF 4D 43 43 02 24

B6

72

D7

Increase "+" : 07 FF 4D 43 43 02 24

B6

2B

1E

Decrease "-" : 07 FF 4D 43 43 02 24

B6

2D

1C

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default MMD: "3" "2"

Default STD: "6" "4"

Graphic Horizontal Resolution

Query

Send Only : 07 FF 4D 43 43 01 25

B7

48

Available response status:

"xxx" = where xxx is a 3-digit HEX

number indicating resolution.

Example:

"0640" = 1600 in decimal

Graphic Vertical Resolution

Query

Send Only : 07 FF 4D 43 43 01 25

B8

47

Available response status:

"xxx" = where xxx is a 3-digit HEX

number indicating resolution.

Example:

"0480" = 1200 in decimal

Graphic Horizontal Sync.

Frequency

Send Only : 07 FF 4D 43 43 01 25

B9

46

Available response status:

"xxx" = where xxx is a 3-digit HEX

number indicating frequency in

units of 100Hz.

Example:

"29F" = 671 or 67.1 kHz decimal

Graphic Vertical Sync.

Frequency

Send Only : 07 FF 4D 43 43 01 25

BA

45

Available response status:

"xxx" = where xxx is a 3-digit

HEX number indicating frequency

in units of 0.1Hz + 1 character

indicating field mode as:

"i" = Interlaced

"p" = Progressive

Example:

"256p" = 598 (59.8 Hz),

progressive fields

Set Address RS / Serial

Syntax : 07 FF 4D 43 43 02 24

BB

xx

zz

Function Examples:
Example "9" : 07 FF 4D 43 43 02 24

BB

39

0B

Where

xx

= "0" to "F"

Where

zz

= Calculated Checksum

Advertising