Appendix

IND100077-124

Notes

Glass Display Control™ (GDC) LED & Button operations:

Prior to the procedure below, it is required you understand the terms and have the nesseccary knowledge how to

interpret the functions in order to successfully use them as described below.

To be able to change GDC buttons and LED functions for the Panel Computers (Maritime Multi Computer - MMC)

Series X product range, the VCOM (Virtual COM port visible in the Operating System (OS) device list as "COM

x

:",

where

x

is OS/configuration dependent number; such as 1, 3 or other) needs to be installed and accessible from

within your system.

The following commands referenced below are only available from GDC Firmware* version

"130225R1" and up.

To determine your unit's GDC Firmware version, send the command

"SWK" via VCOM.

Excerpt from "Message Commands and Queries (CMD) Contents" section in this manual:

0x53

0x57

0x50

"SWK" Glass Display Control™ (GDC) software version Query

R

*Reference Engineering Change Notification (ECN):

http://www.hatteland-display.com/mails/05_2013_ecn.html

Note: It is important to read the GDC LED register (step 1) before you change the bit for your function (Step 3)

Step 1 - Read register GDC LEDs:

- Send Query command: "RBY"

- Data (HEX): 0x93, 0x00

Step 2 - Read register GDC buttons:

- Send Query Command: "RBY"

- Data (HEX): 0x93, 0x07

Step 3 Address only the bit for the function you need to change as illustrated in tables below.

Step 3A - Disable / Enable GDC LEDs:

- Command: "WBY"

- Data (HEX): 0x92, 0x00, 0x

YY

Where "

YY

" is one of the folllowing bits (in a byte):

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

Reserved

ON / OFF

Text

Brilliance

Text

Reserved

Reserved

Brilliance < * >

LED symbols

Power ON/OFF

LED Symbol

All off

0

0 = Off

1 = On

0 = Off

1 = On

0

1 = Normal

(reserved)

0 = Reserved

0 = Off

1 = On

0 = Off

1 = On

1 = active

0 = Reserved

Step 3B - Disable / Enable GDC Buttons:

- Command: "WBY"

- Data (HEX): 0x92,0x07,0x

ZZ

Where "

ZZ

" is one of the folllowing bits (in a byte):

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

Reserved

Reserved

Reserved

Reserved

Power ON / OFF

Button

Outdoor Mode*

Reserved

Brilliance

Button

0

0

0

0

0 = Enable

1 = Disable

0 = Enable

1 = Disable

0

0 = Enable

1 = Disable

*Outdoor mode (Command "MCC - OSD Outdoor Mode") adds 5 seconds to the brilliance buttons before they react.