31 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 31

Advertising
background image

31

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

MCC Command

Syntax and Functionality

Details and Values

Load User Default

Note:

Available function list differs

between MMD and STD units!

Syntax : 07 FF 4D 43 43 02 24

D8

xx

zz

Function Examples:
Example "3" : 07 FF 4D 43 43 02 24

D8

33

F4

Where

xx

= "1" to "5"

Where

zz

= Calculated Checksum

Available functions (MMD):

"0" = Read Defaults

"1" = User1 Slot

"2" = User2 Slot

"3" = User3 Slot

"4" = User4 Slot

"5" = User5 Slot

Available functions (STD):

"0" = Read Defaults

"1" = User Slot

Available response status:

"0" = Fail

"1" = Successful

Swap Main & Second Source

Note:

Not available on STD units.

Send Only : 07 FF 4D 43 43 01 25

E3

1C

Available response status:

"0" = Fail

"1" = Successful

Gamma Reset

Note:

A power off/on to the unit is

required to reboot the internal

display code. This can either be

done by issue the "Power down

/ up" command described earlier

in this table or do a physical

power off/on for the unit.

Send Only : 07 FF 4D 43 43 01 25

E5

1A

Available response status:

"0" = Fail

"1" = Successful

Menu Button

Send Only : 07 FF 4D 43 43 01 25

F7

08

Physical Button press equivalent

Select-Down Button

Send Only : 07 FF 4D 43 43 01 25

FA

05

Physical Button press equivalent

Select-Up Button

Send Only : 07 FF 4D 43 43 01 25

FB

04

Physical Button press equivalent

Right / + Button

Send Only : 07 FF 4D 43 43 01 25

FC

03

Physical Button press equivalent

Left / - Button

Send Only : 07 FF 4D 43 43 01 25

FD

02

Physical Button press equivalent

See next page for "?", "R/r", "+" and "-" command descriptions.