Heath Consultants EyeCGas User Manual

Page 15

Advertising
background image

EYE-C-GAS user's manual

Page 15

P/N PS8G9006-Rev 1

www.heathus.com

www.opgal.com

corresponding item is selected initiates those options and commands. Refer to section 5.1.4 for
details.

5.1.3.5 Mode
The Mode button switches between Normal and Enhanced modes.

While in Normal mode the camera is set for handheld monitoring of the components in the search
for potential leaks.

The second Mode is called Enhanced (ENH). In this mode the camera performs in a high
sensitivity detection mode and the use of a tripod or monopod is recommended to visualize the
leaks of a cluster of components and at a distance.

To enter the ENH mode (see Figure 3), press the Mode button while in Normal mode. After the
button is pressed the keypad configuration will change to that described below in Figure 4.



5.1.3.6 Record / Stop
The Record / Stop button facilitates recording of either visible or infrared video and audio to the
DVR. Depress the Record button once to begin recording and a second time to stop recording.

5.1.3.7 Zoom
The Zoom button scrolls through the electronic zooms. When the button is repeatedly pressed the
zoom increases from x1 to x2 to x4 and back again to x1.

Note: Most of the button functions are also available through the menu.




Zoom

Diff-

Record /
Stop

Enh+

Diff+

Enh-

Normal

Figure 4: Keypad configuration in Enhanced Mode operation