Turning the rmld on – Heath Consultants Remote Methane Leak Detector (RML) User Manual

Page 15

Advertising
background image

Headphone

port

Charger port

RS-232 port

External

Power port

Fig. 3-2: RMLD rear panel

Headphone port: receptacle for the headphone plug.
Charger port: receptacle for the battery charger plug.
Power Switch: depress the switch to turn the instrument on/off.
Ext. Power: receptacle for the external backup battery plug.

Power Switch

RS-232 port: receptacle for a DB-9 connector for interfacing to a PC (Used for
factory calibration purposes only).

Turning the RMLD On

Depress the Power Switch located on the rear panel. When the unit first turns on, the
green Spotter laser will briefly flash, and the display will shortly show all of the icons.
The display will then return to its run display mode showing the ppm-m reading. The
Warning icon will also shortly display as the laser starts up. This warning should turn off
after a few seconds. The instrument will turn on with the same settings (e.g., Alarm
Detection Threshold, Spotter On, etc.) as when it was turned off.

**Note**

The Infrared detection laser is continuously on and the instrument is measuring the
methane concentration while the instrument is on.

Page 15 of 36

101515-0 RMLD MANUAL REV E