C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3

Q: How can I be sure that no protection circuits or safety functions interfere with the output signal?
A: If no Clip or Warning LEDs on the front-panel light up, you can be fully confident that the rated maximum
output power in the full frequency range is available for your speakers. No limiting or gain-reduction takes place
without a warning or fault indication.

6.3 Additional documentation

In case you didn’t find what you were looking for in this Operation Manual, check out the website at
www.labgruppen.com, where you can find a multitude of additional documentation for C Series.

6.4 Current Draw and Thermal Dissipation specification

The following tables contain information on measured current consumption as well as calculated heat dissipa-
tion during normal operation(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).

C 88:4

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

115 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby with remote power off via NomadLink

0

0

0

0

0

Powered on, idling.

139

0

139

475

120

Amp (I)

Watt

Pink noise (1/8
rated power)

8 Ω / Ch.

1250 x 4

17.6

8.8

1177

625

552

1884

475

16 Ω / Bridged

2500 x 2

4 Ω / Ch.

2100 x 4

27

13.5

1914

1050

864

2949

743

8 Ω / Bridged

4200 x 2

2 Ω / Ch.

*4)

2200 x 4

33.6

16.8

2221

1150

1071

3655

921

4 Ω / Bridged

*4)

4400 x 2

100 V / Ch.

2000 x 4

26.2

13.1

1838

1000

838

2860

721

200 V / Bridged

N/R

Pink noise
(max power)
*3)

8 Ω / Ch.

1250 x 4

30.0

16.0

2006/2140

1145/1221

860/918

2935/3133

739/789

16 Ω / Bridged

2500 x 2

4 Ω / Ch.

2100 x 4

30.0

16.0

2127/2268

1230/1312

896/956

3058/3263

770/822

8 Ω / Bridged

4200 x 2

2 Ω / Ch.

2300 x 4

30.0

16.0

1983/2115

1016/1084

966/1031

3297/3519

831/886

4 Ω / Bridged

4600 x 2

100 V / Ch.

2000 x 4

30.0

16.0

5992/2236

3467/1294

883/942

3014/3216

759/810

200 V / Bridged

4000 x 2

Mains connector, 230 V CE version

16 A, CEE7

Mains connector, 115 V ETL version

30A Twist Lock

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation. Note

that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if

operation is momentarily in excess of max. ratings.

*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used

when calculating cooling requirements as they cannot be sustained by the mains breaker over time.

Table 8.4a: C 88:4 Current Draw and Thermal Dissipation specifications