29

6. Appendix

C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3

C 68:4

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

115 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby with remote power off via NomadLink

0

0

0

0

0

Powered on, idling.

133

0

133

454

114

Amp (I)

Watt

Pink noise (1/8
rated power)

8 Ω / Ch.

1200 x 4

16.0

8.0

1123

600

523

1784

450

16 Ω / Bridged

2400 x 2

4 Ω / Ch.

1700 x 4

22.4

11.2

1578

850

728

2484

626

8 Ω / Bridged

3400 x 2

2 Ω / Ch.

1200 x 4

21.2

10.6

1378

600

778

2655

669

4 Ω / Bridged

2400 x 2

100 V / Ch.

1600 x 4

21.0

10.5

1463

800

663

2262

570

200 V / Bridged

3200 x 2

Pink noise
(max power)
*3)

8 Ω / Ch.

1200 x 4

30.0

16.0

2235 / 2384

1472 / 1571

762 / 813

2601 / 2778

655 / 700

16 Ω / Bridged

2400 x 2

4 Ω / Ch.

1700 x 4

30.0

16.0

2085 / 2224

1237 / 1320

848 / 904

2894 / 3089

729 / 778

8 Ω / Bridged

3400 x 2

2 Ω / Ch.

1200 x 4

30.0

16.0

1957 / 2087

1023 / 1091

934 / 996

3188 / 3399

803 / 856

4 Ω / Bridged

2400 x 2

100 V / Ch.

1600 x 4

30.0

16.0

2208 / 2355

1356 / 1446

852 / 909

2908 / 3102

733 / 782

200 V / Bridged

3200 x 2

Mains connector, 230 V CE version

16 A, CEE7

Mains connector, 115 V ETL version

20 A / 5-20P

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation. Note

that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if

operation is momentarily in excess of max. ratings.

Table 8.4b: C 68:4 Current Draw and Thermal Dissipation specifications