31 6. appendix, C 28:4 – Lab.gruppen C Series 88:4 User Manual

Page 38

Advertising
background image

31

6. Appendix

C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3

C 28:4

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

115 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby with remote power off via NomadLink

0

0

0

0

0

Powered on, idling.

123

0

123

420

106

Amp (I)

Watt

Pink noise (1/8
rated power)

8 Ω / Ch.

700 x 4

11.6

5.8

727

350

377

1286

324

16 Ω / Bridged

1400 x 2

4 Ω / Ch.

700 x 4

13.0

6.5

775

350

425

1450

365

8 Ω / Bridged

1400 x 2

2 Ω / Ch.

300 x 4

9.4

4.7

529

150

379

1293

326

4 Ω / Bridged

600 x 2

100 V / Ch.

700 x 4

10.4

5.2

663

350

313

1068

269

200 V / Bridged

1400 x 2

Pink noise
(max power)
*3)

8 Ω / Ch.

700 x 4

24.0

12.0

1589

933

656

2237

564

16 Ω / Bridged

1400 x 2

4 Ω / Ch.

700 x 4

20.8

10.4

1359

700

659

2249

567

8 Ω / Bridged

1400 x 2

4 Ω / Ch.

300 x 4

14.0

7.0

843

300

543

1853

467

8 Ω / Bridged

600 x 2

100 V / Ch.

700 x 4

21.4

10.7

1458

933

525

1790

451

200 V / Bridged

1400 x 2

Mains connector, 230 V CE version

16 A, CEE7

Mains connector, 115 V ETL version

20 A / 5-20P

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation.

Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped

even if operation is momentarily in excess of max. ratings.

Table 8.4d: C 28:4 Current Draw and Thermal Dissipation specifications