6. Appendix

30

C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3

C 48:4

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

115 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby with remote power off via NomadLink

0

0

0

0

0

Powered on, idling.

123

0

123

420

106

Amp (I)

Watt

Pink noise (1/8
rated power)

8 Ω / Ch.

1000 x 4

13,8

6,9

945

500

445

1518

383

16 Ω / Bridged

2000 x 2

4 Ω / Ch.

1200 x 4

17,4

8,7

1171

600

571

1948

491

8 Ω / Bridged

2400 x 2

2 Ω / Ch.

*4)

600 x 4

12,4

6,2

769

300

469

1600

403

4 Ω / Bridged

*4)

1200 x 2

100 V / Ch.

900 x 4

13,2

6,6

840

450

390

1331

335

200 V / Bridged

1800 x 2

Pink noise
(max power)
*3)

8 Ω / Ch.

1000 x 4

28,2

14,1

2116

1333

783

2670

673

16 Ω / Bridged

2000 x 2

4 Ω / Ch.

1200 x 4

30,6

15,3

2168

1200

968

3303

832

8 Ω / Bridged

2400 x 2

4 Ω / Ch.

600 x 4

21,6

10,8

1368

600

768

2620

660

8 Ω / Bridged

1200 x 2

100 V / Ch.

900 x 4

26,4

13,2

1827

1200

627

2139

539

200 V / Bridged

1800 x 2

Mains connector, 230 V CE version

16 A, CEE7

Mains connector, 115 V ETL version

20 A / 5-20P

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation.

Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped

even if operation is momentarily in excess of max. ratings.

*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be

used when calculating cooling requirements as they cannot be sustained by the mains breaker over time.

Table 8.4c: C 48:4 Current Draw and Thermal Dissipation specifications