Section 8 – Miscellaneous Commands

Radiance Mini

rev 091211

28

Zoom Step

This command sets the size of the Zoom step to 5% or 15%. The command is:

MENU → Other → Zoom step → (5%, 15%)

Quick Keys

This adds an optional top-level menu called “Quick Keys” that gives access to functions that are normally
selected using buttons on the Lumagen remote. This menu can be used with programmable remotes that
have limited buttons. You can use the arrow buttons on the remote to highlight one of the functions and
press “Ok” to execute the function. Alternately you can use a number button on the remote to highlight one
of the functions and then press “Ok” to execute the function. (0)4:3, (1)LBOX, (2)16:9, (3)1.85, (4)2.35,
(5)NLS), (6)Zoom+, (7)Zoom-), (8)MemA, (9)MemB, (n/a)MemC, (n/a)MemD, (n/a)3D Off, (n/a)3D SbyS,
(n/a)3D TopB. The command is:

MENU → Quick Keys → (function) → Ok

Configuration Memory Usage

By default, when a configuration memory (A-D) is chosen the selection applies to all inputs. For example if
input 1A is active, then input 2 is selected followed by selecting “MemB,” if input 1 is again selected, it
would use configuration memory 1B. This is called the “Common” configuration memory mode. Generally
this mode is used when specific day and night calibrations are desired and used for all inputs.

You can set the memory usage to be “Per Input.” That is the configuration memory selection is independent
for each input. In this mode, using the example above, starting with input 1A, changing to input 2, pressing
“MemB” and finally selecting input 1, results in using configuration memory 1A. The command is:

MENU → Other → Memory Usage → (Common, Per Input)

Saving the Configuration

Save

NOTE:

If a Save command is not executed after making changes, the changes will be

lost when the unit is put into standby power mode, or if power is interrupted.

Permanently save the current configuration. Note that, once saved, the configuration is retained even if the
unit is disconnected from power. The configuration from the previous save is retained to allow one level of
save-undo. You can use the Radiance Configuration Utility found on the Lumagen.com support page to store
a configuration file on your PC. The command is:

MENU → Save → Save → OK → OK

Undo

Revert to the configuration over-written by the last Save command. Repeating the Save Undo command
toggles between the last two saved configurations. The command is:

MENU → Save → Undo → OK

Restore ISF calibration

During calibration, the video technician can save the resulting Lumagen configuration to a special hidden
configuration memory. This command restores that configuration in the event that the user inadvertently
changes the configuration. A Save is required to make the restore permanent. The command is:

MENU → Save→ Restore ISF→ OK

Revert To Factory Settings

Set all parameters to factory defaults. A SAVE is required to make the settings permanent. The command
is:

MENU 0 9 9 9

Or MENU → Save→ FactoryReset → OK

Advertising