7 safety devices – Martin Christ RVC 2-18 CDplus User Manual

Page 20

Advertising
background image

RVC 2-18 CD&

3 Safety

20

Version 04/2012, Rev. 1.3 of 25/11/2013 • sb

Translation of the original operating manual

Pos: 53 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 006 0-0 060 Siche rheits hinweis e zu r Evap orati on @ 7\m od_ 130 933 104 119 3_68 .docx @ 4 648 7 @ 3 @ 1

3.6.6 Safety instructions for evaporation

The following instructions must be observed prior to every evaporation
process:

WARNING

• Ensure that the RVC was set up and connected properly (see chapter

5 - "Set-up and connection").

• Maintain a safety distance of at least 30 cm (12 inches) around the

RVC.

• Do not store any dangerous goods in the safety area of the RVC.
• Do not stay in the safety area longer than what is absolutely necessary

for the operation of the RVC.

• Only use accessories that have been approved by the manufacturer

(except for commercial vessels made of glass or synthetic materials).
We explicitly warn against the use of equipment of poor quality.
Breaking glass or bursting vessels can cause dangerous imbalances.

• Observe the instructions on the installation of accessories (see chapter

6.4.3 - "Installation of accessories").

Pos: 54 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1

Pos: 55 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 007 0 Sich erh eitsein richtu nge n- --- --- -- --- -- --- -- --- --- -- --- -- --- --- -- --- -- --- -- --- - @ 7\mo d_1 309 331 041 552 _68. docx @ 46 495 @ 2 @ 1

3.7 Safety devices

Pos: 56 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 007 0-0 010 Deck elver rieg elung @ 7\ mo d_1 3093 340 838 55_ 68.d ocx @ 465 35 @ 3 @ 1

3.7.1 Lid lock device

The RVC can only be started when the lid is properly closed. The lid can
only be opened when the rotor has stopped. If the lid is open, the RVC
cannot be started.

Pos: 57 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1

Pos: 58 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 007 0-0 020 Syste mkon trolle @ 7\ mo d_13 093 310 418 96_ 68.d ocx @ 465 03 @ 3 @ 1

3.7.2 System check

An internal system check monitors the data transfer and sensor signals with
regard to plausibility. Errors are detected by continuous self-monitoring of
the system. Error messages are displayed in the process & equipment info

menu (see (see chapter 6.5.3.2 - "Process and equipment information")
or (see chapter 7.2 - "Error messages")).

Pos: 59 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1

Pos: 60 / 200 Christ /37 1 RVC-BA (PROJEKTE) /RVC 2-1 8 CDpl us_2 -18 CD plus_HCl /030 Sicher heit/ 030 -00 70- 003 0 Ne tzausf allsiche rheit 2- 18_ 2-1 8HCl @ 1 2\m od_ 133 541 7298 636 _68 .docx @ 6 4042 @ 3 @ 1

3.7.3 Power failure safety

The unit stores the current process parameters cyclically. In the event of a
power failure, the electromagnetic stop valve towards the vacuum pump will
close automatically, and the rotor decelerates brakeless. The rotor chamber
will not be aerated. After the restart of the power supply, the evaporation
process continues with the last stored parameters.

Pos: 61 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1

Pos: 62 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 007 0-0 040 Schut zleite rpr üfun g @ 7\mo d_1 309 331 042 239 _68. docx @ 46 511 @ 3 @ 1

3.7.4 Earth conductor check

For the earth conductor check, there is an equipotential bonding screw on
the rear panel of the RVC. An earth conductor check can be carried out
with the aid of a suitable measuring instrument.

Pos: 63 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1

Pos: 64 / 200 Christ /37 0 RVC-BA (STANDARDM ODULE)/ 030 Sich erh eit/0 30- 008 0 Ve rhalt en b ei Ge fah ren und U nfälle n @ 7\m od_ 1309 331 042 583 _68. docx @ 46 519 @ 2 @ 1